Assembly instructions
Caution! The voltage of the heating
elements is 230 V. Caution! The earth
cable must be connected to the
terminal when making a connection.
For a single-phase connection
1
230 V, connect terminals 1-2 and
connect the earth cable to
For a two-phase connection
2
400 V / 230 V, connect the earth
cable to
.
L1=R, L2=S, L3=T, N= neutral cable connection, PE=earth connection
Cooker surface
Worktop
Tension clamp
The ceramic hob is designed for operation with a
three-phase household power supply (3*400V/220V
50Hz). The nominal voltage of the heating elements of
the ceramic hob is 230 V. Adaptation of the ceramic
hob to operation with single-phase current is possible
by means of appropriate bridging in the terminal
box according to the connection diagram below. The
connection diagram is also located on the cover of
the terminal box. Remember that the connection cable
should match the connection type and the rated power
of the ceramic hob. The connection cable must be
secured in a strain relief clamp.
Wiring diagram
PE
.
Screw
Recommended
connection
cable
H05VV-F
3G2.5
H05VV-F
4G2.5
EN
27