1 DEFAULT
UK
Read the RESTORE DEFAULT.
I
Leggere il codice che ripristina i default.
F
Lecture du code de configuration par défaut.
D
Lesen Sie den Restore Default Code, um die
Werkseinstellung wieder herzustellen.
RS232 DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking,
ack/nack disabled, fifo enabled, delay disabled, rx timeout 5
sec., serial trigger lock disabled;
DATA FORMAT
code length not transmitted, no header, terminator = CR-LF
character replacement disabled
WEDGE DEFAULT SETTINGS
USA keyboard, caps lock off, num lock unchanged, delays
disabled, control character emulation = ctrl+shift+key;
DATA FORMAT
code length not transmitted, no header, terminator = ENTER
character replacement disabled
PEN EMULATION DEFAULT SETTINGS
interpret mode, conversion to code 39 disabled, output
level normal, idle level normal, minimum output pulse
600 µs, overflow medium
POWER SAVE
standby enabled (button/trigger versions only), Illuminator
off before beep
READING PARAMETERS
trigger type = hardware, trigger signal = level, no timeout,
Flash On = 1 sec, Flash Off = .6 sec, one read per cycle,
safety time .5 sec, beeper intensity high, tone 2, factory
software focus level
RESTORE DEFAULT