BTL7-A/C/E/G5 _ _ -M _ _ _ _ -H/W(8)-S32/S115/_ _ _
Micropulse Transducer - Rod Style
4
Installation and connection (continued)
4.4.3
Cable connection
Cable color
-A510
YE yellow
Not used
GY gray
PK pink
10...0 V
10...–10 V
RD red
GN green
0...10 V
–10...10 V
BU blue
BN brown
WH white
Unassigned leads can be connected to the GND on the controller side but not to the shield.
1)
Reference potential for supply voltage and EMC-GND.
2)
3)
The voltage outputs may exhibit a minimal offset to the harmonized current output.
Tab. 4-4:
Cable assignment BTL7... cable
4.5
Shielding and cable routing
Defined ground!
The transducer and the control cabinet must be
at the same ground potential.
Shielding
To ensure electromagnetic compatibility (EMC), observe
the following:
Connect transducer and controller using a shielded
cable.
Shielding: Braided copper shield with minimum 85%.
Connector version: Shield is internally connected to
connector housing.
Cable version: On the transducer side, the cable
shielding is connected to the housing. Ground the
cable shielding on the controller side (connect with the
protective earth conductor).
Magnetic fields
The linear encoder is a magnetostrictive system. It is
important to maintain adequate distance between the
transducer/holding cylinder and strong, external magnetic
fields.
Cable routing
Do not route the cable between the transducer, controller,
and power supply near high voltage cables (inductive stray
noise is possible).
The cable must be routed tension-free.
Bending radius for fixed cable
The bending radius for a fixed cable must be at least five
times the cable diameter.
www.balluff.com
All manuals and user guides at all-guides.com
-G510
-C500
-C570
1)
0...20 mA
20...0 mA
0 V
La (programming input)
GND
2)
10...30 V
Lb (programming input)
-E500
-E570
4...20 mA
20...4 mA
10...0 V
3)
0...10 V
3)
Cable length
BTL7-A/G
Max. 30 m
BTL7-C/E
Max. 100 m
Prerequisite: Construction, shielding and routing preclude the effect of any
1)
external noise fields.
Tab. 4-5:
Cable lengths BTL7
1)
1)