16
Connecting to terminals:
1. You can get to the screen through a slit in the cable sheath (see Fig. 6.1).
2. Lay the screen flat on the housing frame.
Attaching to a connector:
Lay the cable shield flat on the connector housing.
10
Fig. 6.1: Slit cable sheath
Six‐wire connection
Fig. 6.2: Pin assignment for the U3
HBM
100
10
wh (white)
bk (black)
rd (red)
bl (blue)
gn (green)
gy (grey)
ye (yellow)
2
Cable sheath cut open at the circumference
and pushed forward by approx 2mm
Measurement signal (+) U
Excitation voltage (-) U
Measurement signal (-) U
Excitation voltage (+) U
Sensor circuit (+)
Sensor circuit (-)
Cable shielding, connected to housing