Télécharger Imprimer la page

HBM U3 Notice De Montage page 14

Publicité

14
5.3.3 Installation with two knuckle eyes
Fig. 5.5
Installation for tensile loading with two knuckle eyes
Nominal
H(mm)
force (kN)
0.5 - 10
153
20
232
50
256
100
300
Attaching the knuckle eye:
• Screw the correct adapter (dependent on nominal force!) to the U3 (please
note screw length)
• Turn the lock nut back as far as the eye
• Screw the knuckle eye into the adapter as far as the stop
CAUTION
Do not apply force to the transducer flange.
• Unscrew knuckle eye 1 to 2 turns and align
• Load eye with nominal load
• Tighten lock nut (M
CAUTION
When locking with the lock nut, under no circumstances let the torque
be transmitted through the transducer.
HBM
M
B
M2 (M
M1 (M
M
B
Starting torque M
A
(NVm)
5
40
40
94
, lock using the flat of the adapter)
B
)
A
base
flange
)
A
Starting torque M
B
(NVm)
60
300
500
1000
U3
Screws for adapter
mounting
M1
M2
M5x12
M5x16
M10x25
M10x30
M10x25
M10x30
M10x25
M10x30
A2113-2.0 en/de/fr

Publicité

loading