5.3.3 Installation with two knuckle eyes
Fig. 5.5
Installation for tensile loading with two knuckle eyes
Nominal
H(mm)
force (kN)
0.5 - 10
153
20
232
50
256
100
300
Attaching the knuckle eye:
• Screw the correct adapter (dependent on nominal force!) to the U3 (please
note screw length)
• Turn the lock nut back as far as the eye
• Screw the knuckle eye into the adapter as far as the stop
CAUTION
Do not apply force to the transducer flange.
• Unscrew knuckle eye 1 to 2 turns and align
• Load eye with nominal load
• Tighten lock nut (M
CAUTION
When locking with the lock nut, under no circumstances let the torque
be transmitted through the transducer.
HBM
M
B
M2 (M
M1 (M
M
B
Starting torque M
A
(NVm)
5
40
40
94
, lock using the flat of the adapter)
B
)
A
base
flange
)
A
Starting torque M
B
(NVm)
60
300
500
1000
U3
Screws for adapter
mounting
M1
M2
M5x12
M5x16
M10x25
M10x30
M10x25
M10x30
M10x25
M10x30