Important Considerations
Before installing the appliance, you must read the manual carefully to get the safety
information and notes.
Unit refrigerant charge amount: refer to unit name plate marking.
A leak test must be done after the installation is completed.
It is a must to do the safety inspection before maintaining or repairing an air
conditioner using combustible refrigerant in order to ensure that the fire risk is
reduced to minimum.
It is necessary to operate the machine under a controlled procedure in order to
ensure that any risk arising from the combustible gas or vapor during the operation
is reduced to minimum.
Introduction to Refrigerants R32(Only for R32 Model)
1. Site Safety
2. Operation Safety
Mind Static Electricity
3. Installation Safety
Refrigerant Leak Detector
Appropriate Installation Location
Please note that:
1. The installation site should be in a well-ventilated condition.
2. The sites for installing and maintaining an air conditioner using Refrigerant R32 should be free from open fire
or welding, smoking, drying oven or any other heat source higher than 548
3. When installing an air conditioner, it is necessary to take appropriate anti-static measures such as wear
anti-static clothing and/or gloves.
4. It is necessary to choose the site convenient for installation or maintenance wherein the air inlets and outlets of
the indoor and outdoor units should be not surrounded by obstacles or close to any heat source or combustible
and/or explosive environment.
5. If the indoor unit suffers refrigerant leak during the installation, all the personnel should go out till the refrigerant
leaks completely for 15 minutes. If the product is damaged, it is a must to carry such damaged product back to
the maintenance station and it is prohibited to weld the refrigerant pipe or conduct other operations on the user's
site.
6. It is necessary to choose the place where the inlet and outlet air of the indoor unit is even.
7. It is necessary to avoid the places where there are other electrical products, power switch plugs and sockets,
kitchen cabinet, bed, sofa and other valuables right under the lines on two sides of the indoor unit, and also
prevent mechanical damage from occurring.
Open Flames Prohibited
Open Flames Prohibited
Must Wear Protective Clothing and anti-static gloves
The left picture is the schematic diagram of a refrigerant leak detector.
which easily produces open fire.
9
Ventilation Necessary
Don't use mobile phone