Publicité

3
TEST INSTALLED FAUCET
• Remove AERATOR. With handles in OFF position, turn
on water supplies and check all connections for leaks.
• Operate both handles to flush water lines thoroughly.
Replace AERATOR.
4
SERVICE
CAUTION
If Faucet Drips, Proceed As Follows:
• Turn HANDLES to OFF position.
• If spout drips, operate HANDLES several times from OFF to ON position. Do not force HANDLES they turn only 90˚.
• AERATOR may accumulate dirt causing distorted and reduced water flow. Remove AERATOR and clean before reinstalling.
Change Handle Direction:
• Lift up HANDLE (1).
• Remove Plastic ADAPTER (2) and CARTRIDGE NUT (3).
• Lift and turn STOP WASHER 90˚.
• Re-install HANDLE components.
To Change Cartridge:
• Lift up HANDLE (1).
• Remove Plastic ADAPTER (2) and CARTRIDGE NUT (3).
• Lift CARTRIDGE (4) off PORT (5).
• Clean CARTRIDGE (4) port.
• Place CARTRIDGE (4) onto PORT (5) and tighten CARTRIDGE NUT (3) alternately.
• Replace Plastic ADAPTER (2), HANDLE (1).
90°
6
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
Turn off hot and cold water
supplies before beginning.
90°
AERATOR
1