Base Grille Water Filtration System
Model P2WG2L/P2RFWG2
Capacity
200 Gallons
(757 Liters)
Model
P2WG2/P2RFWG2
Capacity
200 Gallons
(757 Liters)
System
tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine
Taste and Odor, Particulate
Class I*; and against
NSF/ANSI
Standard
53 for the reduction
of Lead,
Mercury,
Benzene,
Toxaphene,
and O-dichlorobenzene.
This system
has been tested according
to NSF/ANSI
Standards
42 and 53 for the reduction
of the substances
listed below. The
concentration
of the indicated
substances
in water entering
the system
was reduced
to a concentration
less than or equal to the
permissible
limit for water leaving the system,
as specified
in NSF/ANSI
Standards
42 and 53.
Substance
Reduction
Aesthetic
Effects
Chlorine Taste/Odor
Particulate Class I*
Contaminant
Reduction
Lead: @ pH 6.5
Lead: @ pH 8.5
Mercury: @ pH 6.5
Mercury: @ pH 8.5
Benzene
O-Dichlorobenzene
Toxaphene
NSF Reduction
Requirements
50% reduction
85% reduction
NSF Reduction
Requirements
0.010 mg/L
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.005 mg/L
0.6 mg/L
0.003 mg/L
Average
Influent Challenge
Influent
Concentration
1.909 mg/L
2.0 mg/L + 10%
9700000 #/mL
At east 10,000 part c es/mL
Average
Influent
143.33 ug/L
140 ug/L
0.0058 mg/L
0.00646 mg/L
0.015 mg/L
1.83333 mg/L
0.016 mg/L
Influent Challenge
Concentration
0.15 mg/L_+ 10%
0.15 mg/L_+ 10%
0.006 mg/L _+10%
0.006 mg/L _+10%
0.015 mg/L _+10%
1.8 mg/L _+10%
0.015 mg/L _+10%
Maximum
Average
Effluent
Effluent
0.05 mg/L **
<0.05 mg/L
2600 #/mL
62000 #/mL
Maximum
Effluent
1.0 ug/L
1.0 ug/L
0.3 ug/L
1.4 ug/L
0.5 ug/L
4.8 ug/L
1 ug/L
Average
Effluent
1.0 ug/L
1.0 ug/L
0.0002 mg/L
0.0004 mg/L
0.0005 mg/L
0.014 mg/L
0.001 mg/L
Minimum %
Reduction
>97.4
>97.6
Minimum %
Reduction
>99.3
>99.3
>96.5
76.3
>96.5
99.7
>93.2
Average %
Reduction
>97.4
>99.4
Average %
Reduction
>99.3
99.3
96.5
88.1
>96.5
99.9
>93.2
Test Parameters: pH = 7.5 + 0.5 unless otherwise noted. Flow = 0.85 gpm (3.2 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
•
It is essential
that operational,
maintenance,
and filter
replacement
requirements
be carried
out for the product
to
perform
as advertised.
•
Use replacement
filter P2RFWG2,
part #4396841.
2008 suggested
retail price of $39.99
U.S.A./S54.95
Canada.
Prices are subject
to change without
notice.
Model P2WG2L/P2WG2:
Style
1 - When the filter indicator
reads 10%, order a new filter. When the indicator
reads 0%, it is
recommended
that you replace the filter.
Style 2 - When the filter indicator
changes
from green to yellow,
order a new filter. When the indicator
changes
from yellow to red,
it is recommended
that you replace the filter.
Style 3 - When the water filter status display changes
from
"GOOD"
to "ORDER,"
order a new filter. When the filter indicator
reads "REPLACE,"
it is recommended
that you replace the filter.
Style 4 - Press FILTER to check the status of your water filter. If
the filter indicator
light is yellow, order a new filter. If the filter
indicator
light is red, it is recommended
that you replace the filter.
Change
the water filter cartridge
every 6 months.
If the water
flow to the water dispenser
or ice maker decreases
noticeably
before 6 months
have passed,
replace the water filter cartridge
more often.
•
These contaminants
are not necessarily
in your water supply.
While testing
was performed
under standard
laboratory
conditions,
actual performance
may vary.
•
The product
is for cold water use only.
•
Do not use with water that is microbiologically
unsafe or of
unknown
quality
without
adequate
disinfection
before or after the
system.
•
Refer to the "Warranty"
section
for the Manufacturer's
name,
address
and telephone
number.
•
Refer to the "Warranty"
section
for the Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
30 - 120 psi (207 - 827 kPa)
33 ° - 100°F (0.6 ° - 37.8°C)
0.85 gpm (3.2 Lpm) @ 60 psi
*Class I particle size: >0.5 um to <1 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
® NSF is a registered trademark
of NSF International.
12