TROUBLESHOOTING GUIDE
DEVICE
Battery Charger LED does not indicate activity when
Charger
the charger and battery are plugged in.
Battery Charger LED blinks RED or GREEN or is solid
Charger
GREEN when the battery is not attached to it.
Battery Charger LED blinks RED once and stops for
Charger
two seconds. It repeats five times, when the battery
Battery Charger LED blinks RED twice and stops for
Charger
two seconds. It repeats five times, when the battery
Battery Charger LED blinks RED five times and stops
Charger
for two seconds. It repeats five times, when the
Battery Charger LED blinks green when the battery is
installed and shortly thereafter turns solid green. This
Charger
process repeats itself. However, the battery is not
fully charged when you depress the battery button.
Battery
Battery LED1-LED4 flashes two times, stops for 1.2
Battery on Unit
seconds and then turn off after five occurances
Battery LED1-LED4 flash four times, stops for 1.2
Battery on Unit
seconds and then turn off after five occurances
Battery LED1-LED4 flash five times, stops for 1.2
Battery on Unit
seconds and then turn off after five occurances
Powerhead will NOT start, and the Battery LEDs do
Battery on Unit
Powerhead makes a "clicking noise" from the top
of the motor cover, and will not turn. Battery LEDs
Unit
indicate a full charge. With Battery disconnected,
transmission output can be turned by hand, in either
Get parts online at www.getearthquake.com or call 800-345-6007 M-F 8-4:30 CST.
PROBLEM
is attached to it.
is attached to it.
battery is attached to it.
Battery LED's do not illuminate.
during operation.
during operation.
during operation.
NOT illuminate.
direction.
POSSIBLE CAUSE
Battery Charger is defective.
Battery Charger is defective.
Battery is too cold.
Battery is too hot.
Battery voltage is too low.
Battery/charger is too hot/cold.
Battery is dead or defective.
Discharge high temperature.
Overvoltage protection.
Overload protection.
Battery is dead or defective.
Motor is trying to turn, but cannot
due to low or incomplete voltage to
the motor.
Operator Manual
60V Cultivator
REMEDY/ACTION
Replace battery charger.
Replace battery charger.
Take battery to warm location for
60 minutes.
Take battery to cool location for
60 minutes.
Replace battery.
Take battery/charger to warm/
cool location.
Charge or replace the battery.
Take battery to cool location for
60 minutes.
Contact Customer Service.
Remove possible obstruction
near working end of tool.
Replace or charger battery.
Remove motor cover and check
connections. If all connections
are tight replace controller.
11