PARAMETER
Led output management mode in closing movement:
0 = output disabled
1 = LED fixed on and OFF at the end of the movement
CLM
11
2 = LED fixed on and ON at the end of the movement
3 = LED flashes and OFF at end of movement
4 = LED flashes and ON at end of movement
Flashing mode of the Leds:
0 = normal impulse
1 = short impulse
bLM
12
2 = normal and soft impulse
3 = short and soft impulse
4 = flashing softly
Mode of action of the current sensor:
0 = no action
SnM
13
1 = intervention on mechanical stop and obstacle
2 = intervention on obstacle
3 = intervention on mechanical stop
SIt
14
Current sensor intervention time.
Sdt
15
Current sensor override time at cue.
Action to be performed on obstacle detection in closing:
ibM
16
0 = brief inversion of movement
1 = total opening
UrA
17
Duration of the acceleration ramp (from 0 to SPn)
Duration of the slow-down ramp in the opening movement
drAO
18
(from SPno to SPLo)
Duration of the slow-down ramp in the closing movement
draC
19
(from SPnc to SPLc)
Choice of devices to perform the functionality test:
0 = no device to test
1 = PH1
2 = PH2
tPh
20
3 = PH1 + PH2
4 = PH3
5 = PH3 + PH1
6 = PH3 + PH2
7 = PH3 + PH2 + PH1
Configuration of the flashing output:
FPr
21
0 = fixed on
1 = flashes
tPr
22
Time of light flashing, before the movement start.
28 / 36 - English
All manuals and user guides at all-guides.com
DESCRIPTION
DEFAULT
MIN
MAX
CUSTOM
1
0
4
0
0
4
1
0
3
2
1
10
15
0
30
0
0
1
15
0
20
6
0
20
6
0
20
0
0
7
1
0
1
0
0
10
6-1622396 - rev. 3 - 21/09/2021
UM
x100ms
x100ms
x100ms
x100ms
x100ms
s