PARAMETER
SPNo
5
Speed when fully operational during opening.
SPNc
6
Speed when fully operational during closing.
SPLo
7
Slow-down speed during opening.
SPLc
8
Slow-down speed during closing.
SS configuration:
0 = normal (AP-ST-CH-ST-AP-ST...).
sbs
9
1 = alternated with STOP (AP-ST-CH-AP-ST-CH...).
2 = alternated (AP-CH-AP-CH...).
Behaviour after blackout:
0 = no action.
blt
10
1 = performs opening movement.
2 = performs closing movement.
Amplitude slowing in opening.
LSIo
11
%100...0 = percentage of the ride.
Amplitude slowing in closing.
LSIc
12
%100...0 = percentage of the ride.
asL
13
Antiskid / Extra-time run.
How to use the encoder:
0 = not used
ENC
14
1 = Detect obstacle and position
2 = Detect obstacle
3 = Detect position
1. TIME FOR AUTOMATIC CLOSING tCL (0 – 900 seconds) default = 0
It activates at a steady automation in the total opening position, the automation closes after waiting for the tCL time. At this stage
the display shows -tc with the dash flashing, which in the last ten seconds is replaced by the countdown. An opening command
or photocell intervention restarts the count.
2. TIME FOR AUTOMATIC CLOSING AFTER TRANSIT ttr (0 – 30 seconds) default = 0
If during the opening or during the opening permanence the beam of the photocells has been obscured and then released, the
automation closes after having waited the time ttr once reached the total opening position. At this stage the display shows -tc
with the dash flashing, which in the last ten seconds is replaced by the countdown.
3. SENSIVITY ON OBSTACLE AT FULL SPEED SEn (0 – 100 %) default = 40%
Adjust the sensitivity on obstacle in order to obtain a proper functioning of the automation, intervening in case of obstacle but
such as to ensure the movement even in the worst operating conditions (e.g. winter, hardening of motors due to wear, etc.). It is
recommended after adjusting the parameter to perform a full movement of opening and closing, before checking the intervention
on obstacle. Lower values correspond to a greater thrust on the obstacle.
6-1622396 - rev. 3 - 21/09/2021
All manuals and user guides at all-guides.com
DESCRIPTION
DEFAULT
MIN
MAX
CUSTOM
100
50
100
100
50
100
30
10
100
30
10
100
0
0
2
0
0
2
25
0
100
25
0
100
15
0
300
3
0
3
English - 25 / 36
UM
%
%
%
%
%
%
s