Télécharger Imprimer la page

STEINEL IS 2180-ECO Manuel D'instructions page 14

Publicité

GB
Dear Customer,
Congratulations on purchas-
ing this STEINEL Infrared
Sensor and thank you for
the confidence you have
shown in us. You have cho-
sen a high-quality product
that has been manufac-
tured, tested and packed
with the greatest care.
1. System components
Security screw
1
Front cover
2
3
Lens (can be removed
and turned for selecting
the max. basic reach
settings of 5 m or 12 m)
2. Technical specifications
Dimensions (H × W × D):
Output:
Incandescent / halogen lamp load: 2,000 W
LED / ECG load: 350 W (50 units, c < 132 μF)
Connection:
Detection angle:
Sensor reach:
Time setting:
Light threshold:
Enclosure:
Temperature range:
Please familiarise yourself
with these instructions
before attempting to install
the sensor since prolonged
reliable and trouble-free op-
eration will only be ensured
if it is installed properly.
Light threshold setting
4
control 2 – 2,000 lux
Time setting control
5
10 sec. – 15 min.
120 × 78 × 55 mm
230 – 240 V, 50 Hz
180° horizontal, 90° vertical
basic setting 1: 5 m max.
basic setting 2: 12 m max. (factory setting)
+ precision adjustment from 1 – 12 m by means
of clip-on shrouds
10 sec. – 15 min. (factory setting: 10 sec.)
2 – 2,000 lux (factory setting: 2,000 lux)
IP 54
-20 °C to +50 °C
– 14 –
We hope your new Infrared
Sensor will give you lasting
satisfaction.
6
Clip (housing can be
flipped up for assembly
and connection to mains
power supply)

Publicité