Les langues disponibles

There is a risk for eye injury, especially if a
spring is broken.
1. Remove the bolt in the center of the starter pulley
and remove the starter pulley. Carefully remove the
cover.
The recoil spring has tension in the starter housing.
2. Carefully remove the spring. Use a pair of pliers.
To clean the spring assembly
CAUTION:
from the assembly.
1. Blow the spring with compressed air until it is clean.
2. Apply a light oil to the spring.
34
Do not remove the spring
To attach the spring assembly
Assemble in the opposite sequence of
the spring assembly on page 33 .
To install the starter housing
CAUTION:
come into the correct position against the
starter pulley sleeve.
1. Put the starter against the product.
2. Install the starter pawls into the correct position
against the starter pulley sleeve. Pull out the starter
rope approximately 0.5 m. (A). If the position is
correct, you hear a click sound (B).
B
3. Slowly release the starter rope.
To remove
The starter pawls must