- GB -
Pos: 41 /Filter/BioSmart 8000, 16000/Lagern/Überwintern BioSmart 8000/16000 @ 4\mod_1155647570120_121.doc @ 24431 @
Storage/Over-wintering
Put the unit out of operation at water temperatures below 8 °C or, at the latest, when freezing temperatures are to be
expected. Drain and thoroughly clean the flow-through filter, check for damage. Remove, clean, dry and store all filters
in a frost-free environment. Do not immerse the power plug in the water! Cover the filter container such that the ingress
of rain water is excluded. Drain all hoses, pipes and connections as far as possible. Ensure that the storage place is
inaccessible to children.
Pos: 42 /Filter/BioSmart 8000, 16000/Verschleißteile BioSmart 8000/16000 @ 4\mod_1155647409958_121.doc @ 24405 @
Wear parts
The UVC lamp, the quartz glass and the foam filters are wear parts and are excluded from the warranty.
Pos: 43 /Alle Produkte/Entsorgung mit UVC @ 2\mod_1137146293332_121.doc @ 13332 @
Disposal
Dispose of the unit in accordance with the national legal regulations. The UVC lamp needs special disposal. Ask your
specialist dealer.
Pos: 44 /Filter/PondoClear Set/Störung PondoClear @ 2\mod_1137142938294_121.doc @ 13075 @
Malfunctions
Malfunction
The unit performance is not satisfactory
UVC lamp display is not lit
No water outlet from the pond inlet
Pos: 45 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1631 @
10
Cause
Unit has been in operation only for a short time
Water extremely soiled
Excessive fish and animal population
Foam filters soiled
Pump filter housing soiled
Impeller unit blocked
Quartz glass tube soiled
UVC lamp capacity exhausted
Power supply of UVC not connected
UVC lamp defective
Connection defective
UVC overheated
Pump power supply not connected
Pond inlet blocked
Remedy
The complete biological cleaning effect is only
achieved after several weeks
Remove algae and leaves from the pond,
perform a partial water change
Guide value: approx. 60 cm fish length in 1 m³
pond water
Clean filters
Clean pump filter housing
Clean pump
Remove UVC and clean quartz glass
Replace the lamp after approx. 8,000 operating
hours
Connect UVC power plug
Replacing the UVC lamp
Check electrical connection
UVC automatically switches on when cooled
down
Connect pump power supply
Clean pond inlet

Publicité

loading

Ce manuel est également adapté pour:

Biosmart 14000