GB
2. Transport, installation and
operating instructions
These instructions apply for the CEMO UNI-/MULTI-Tank 400 l
in ac cordance with the general construction inspection approval
Z-40.21-365.
If this tank is to be used in accordance with the standard
EN 13341, the "Ü" mark on the type plate must be covered
by the enclosed sticker with the CE mark.
The CEMO UNI-/MULTI-Tanks are supplied as a unit
with an impact-proof cover of recyclable material held in
place by a shrink-wrap as protection during transportation.
The level indicator can be found in the cover on the tank
side. The tanks are fitted with a leak sensor in the works.
The base at MULTI-Tank is already fitted in the works. The
cover should only be removed at the place of installation!
The approval certificate with transport, installation and
operating instructions, inspection declaration and warranty
document can be found in an envelope in a tank connec-
tion piece.
The tanks may only be installed in a fully enclosed room.
An additional collecting room is not required!
The tank must be installed at least 1 m from any furnaces
(fireplaces, chimneys, connecting pieces).
The tanks may not be installed in
a) passages,
b) staircases,
c) generally accessible corridors,
d) on the roofs of residential buildings,
hospitals, office buildings and similar
buildings or in their attics,
e) offices,
f) in guest rooms and bars.
The tanks may only be filled with heating oil or diesel
fuel using a free inlet without a fixed connection of the
filling line.
Insert the level indicator in the upper connection piece.
The cap has to be removed beforehand, slide the union nut
over the indicator from below and screw the threaded liner
into place. Then fasten the level indicator by screwing the
union nut onto the connection piece using the en closed
seal.
The tanks can also be connected with a fixed connection
for automatic removal via submerged-pumpsor pumps
with subsequent accumulator. In this case the systems
should be fitted with an automatic safety device to prevent
a siphon effect.
12
If operated with an automatic removal the tanks must be
adequately ventilated, e.g. through the use of an aeration
and ventilation insert (2") that can be mounted in the exist-
ing threaded liner.
The overfill safety device with the order no. 7330 is avail-
able as an accessory for storing nonflammable media and
the specified connection.
The leak sensor with the order no. 7391 is available as an
accessory for storing used lubricating, hydraulic or thermal
oils.
3. Inspection declaration
Inspection declaration
for CEMO UNI- / MULTI-Tank 400 l
of high-density polyethylene and galvanised sheet steel
for the unpressurised storage of media
according to the general construction inspection ap-
proval Z-40.21-365.
Article No.:
7536/7979
Tank content:
400 l
Test pressure:
0.3 bar
Approval number: Z-40.21-365
We confirm that the tank complies with the provisions
of the general construction inspection approval. The
construction and leak tests have been performed.
The Works Experts:
CEMO GmbH