Important
Any activity connected with regulation etc. must be done only when the device is
disconnected from electricity. If it is necessary to have the device connected to the electricity
(durig regulation) you must be very careful.
PLACEMENT
The device must be instalated in well ventilated room what is necessary for regulation of the
function of the device (technician must go by valid standard). If the device is situated close to
the wall or if it is in contact with the furniture walls, these walls must resist the temperatures
ranging to 60°C. Instalation, setting, putting into operation must be done by qualified person
who is competent for this and according to the valid standards.
Wrap up the device and check whether it was not damaged during transport. Settle the device
on horizontal surface (max imbalance 2°). Settle the device under the fumehood to eliminate
water steam and bad smell.
The device can be instalated separately or in a set with devices of our production. Min.
distance 10 cm from other subjects must be kept. It is also necessary to prevent our product
from contact with combustible materials. In this case you must make corresponding changes
to secure heat izolation of combustible parts.
SAFETY MEASURES FROM THE STANDPOINT OF THE FIRE PROTECTION
• only adults can operate the device
• device must be safely used in common surroundings
• device must be placed so as to stand or hang on the noncombustible surface
No subjects from combustible materials can be placed directly on the device or in distance
which is shorter than safety distance (the shortest distance is 10 cm).
• safety distances from various materials of different degree of combustion and
information about the degree of comb. of common building materials - see chart:
Chart
combustion degree of building materials classified according to the combustion degree of
materials and products
A noncombustible
granit, sandstone, concretes,bricks, ceramic wallfacing tiles,
5