XMS Instruction Manual
Input Parameters
Standard
Nominal input voltage
Input voltage range
Input frequency range
Maximum input current
* Input for 350W models.
All ratings apply for ambient temperatures up to 50°C.
Output Parameters
Outputs are not user adjustable but can be factory set.
Output Channel
CH1(500W)
-
-
-
-
CH1(350W)
-
Standby Option
-
-
-
-
Fan Supply
-
-
-
* 576W peak power for 2 minutes with 500Wrms max using the formula below:
500Wrms =
Where
T1 = peakpower time on in seconds
T2 = reducedpower time on in seconds
Non-standard models:
MODEL
DESCRIPTION
X00011#
XMS350-24-NN-N1CBLEN
X00023#
XMS500D-24.5-5C-KFCBDEN
X00073#
XMS500-24-NN-NCBRInA
Where # indicates any letters denoting non-safety related changes.
Output Limitations
All outputs are SELV in accordance with 60950-1.
Model
designation
-
12
-
24
-
36
-
40
-
48
-
24
-
-
5
-
5
-
12
-
N
-
-
N
-
N1
-
N2
-
N3
60950-1, 62368-1, 60601-1
Vout nom.(V)
Range (V)
12
11.6 – 13.2
24
23.8 – 25.2
36
35.4 – 37.8
40
38 – 42
48
47 - 50
24
23.8 – 25.2
-
5
5 - 5.5
5
5 – 5.5
12
12 – 13.2
10
5 - 15
-
-
24
Fixed
12
6 – 12
12
Fixed
COMMENTS
Customer specific chassis
Customer specific top fan/chassis model
Standard chassis, customer specific cover
Page 16 of 24
100 - 240 Vac
90 - 264Vac
47 - 63Hz
7A (5.3A*) rms
Output
Current (A)
41.6
20.8
13.8 (16*)
12.5
(15.16*)
10.4 (12*)
14.6
-
-
0.5
2
1
0
-
-
-
-
0.2
-
0.25
260217 issue 13, Nov 2021
Output
Power (W)
500
500
500 (576*)
500 (576*)
500 (576*)
350
-
2.75
11
13.2
0
-
-
4.8
3
3