XMS Instruction Manual
Environmental Specifications:
Description
Use
Temperature
Humidity
Altitude
Pressure
Orientation
Material Group
Pollution Degree
Overvoltage Category
Class
Weight
IP Rating
* 5000m (54kPa) for 60950-1 and 62368-1 only, 4000m (61.64kPa) for 60601-1 3
60601-1 2
nd
Edition
Level of Insulation:
Dielectric Strength testing is carried out as follows:
Primary mains circuit to earth: 2.68kVdc
Primary mains circuits to secondary: 6.863kVdc*
Secondary circuits to earth: 2.13KVdc
*Important Note: This test is not possible with Y capacitors fitted to the unit as damage to these
capacitors may occur.
Routine Dielectric Strength testing is carried out as follows:
Class I Products: Primary mains circuit to Secondary circuits and earth shorted together 2.25kVdc to 2.35kVdc.
Secondary circuits to earth 2.25kVdc to 2.35kVdc.
Class II products: Primary mains circuit to Secondary circuits 4.25kVdc to 4.35kVdc.
Safety approvals
UL60950-1 and CSA22.2 No.60950-1 - UL Recognised. C-UL for Canada.
UL62368-1 and CSA22.2 No.62368-1 - UL Recognised. C-UL for Canada.
UL/CSA 60601-1/ANSI/AAMI ES 60601-1 - UL + C -UL approval
IEC/EN60950-1, IEC/EN 62368-1 and IEC/EN60601-1 - CB Report and Certificate.
IEC/EN62368-1 – CE and UKCA mark.
CE marking when applied to any QM and/or QS product, indicates compliance with the Low Voltage Directive in that
it complies with EN62368-1 and with the RoHS Directive.
UKCA marking when applied to any QM and/or QS product indicates compliance with the Electrical Equipment
(Safety) Regulations 2016 in that it complies with EN62368-1 and with the Restriction of the Use of Certain
Hazardous Substances in Electrical and Electronic Equipment Regulations 2012
Fusing: Internal fuses (F1): dual fuses in the L and N line or single fuse in the Live/+ Line, F10AH or F8AH, 250V,
5x20mm.
Symbols:
AC
EARTH
Caution
Note: All output voltages/variants may not be available as standard units, refer to datasheet for standard
product range. These (and other variants) may be available as non-standard or custom units. Please contact
our sales team for details.
Operation
Indoor
0°C to +50°C
5 - 95% RH, non-condensing
-200m to 5000m*
54kPa (5000m)* - 106kPa
The unit may be mounted in any orientation except
inverted (mounted on its top)
N – Neutral
L – Live
Warning: Dangerous Voltage
IIIb
2
II
I or II
1 kg max
IPX0
Page 14 of 24
Storage & Transportation
-
-40°C to +70°C
5 - 95% RH, non-condensing
-200m - 5000m
54kPa - 106kPa
ALL
Edition and 3000m (70kPa) for