Switching on, switching off (Figure E)
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures: Disconnect the power plug prior to reaching into the water and commencing work.
The unit switches on automatically when power connection is established.
Switching on: Plug the power plug (16) into the socket.
Switching off: Disconnect the power plug (16).
Cleaning
Disconnect the power plug (16) prior to starting cleaning work!
If necessary, clean the filter housing under clear water using a soft brush.
Malfunction
Malfunction
Pump does not start
Pump does not deliver, insufficient delivered
quantity
Pump switches off after a short running time
Storage/Over-wintering (F-H)
Take the unit out of operation when temperatures below zero are to be expected. Remove the unit from the water, un-
screw the injector (3) from the outlet (4) and remove the grip screw (7).
Remove the two grip screws (17) and take the drum (5) off the floating body (1). Clean the floating body (1) and the
drum (5) under running cold water.
Store the drum (5) submerged in a container filled with water. Do not immerse the power plug in the water! Ensure that
the storage place is inaccessible to children.
Store the floating body (1) in a dry and frost protected place.
Cause
No mains voltage
Drum blocked
Excessively soiled water
Water temperature too high
Remedy
Check mains voltage
Clean, check supply lines
Clean drum
Clean pump
Note maximum water temperature of +35°C
- EN -
9