SET
POWER
ON/OFF
PRESET
<Preset Number>
SLEVEL
<Source>
OLEVEL
<Output Channel>
XLEVEL
<Input Channel> <Source>
GLEVEL
<Loc/Net/Gen>
SMUTE
<Source>
OMUTE
<Output Channel>
XMUTE
<Input Channel> <Source>
GMUTE
<Loc/Net/Gen>
ZONERIN
<Output>
GPO
<Output>
INC
SLEVEL
<Source>
OLEVEL
<Output Channel>
XLEVEL
<Input Channel> <Source>
GLEVEL
<Loc/Net/Gen>
DEC
SLEVEL
<Source>
OLEVEL
<Output Channel>
XLEVEL
<Input Channel> <Source>
GLEVEL
<Loc/Net/Gen>
SUBSCRIBE
ALL
SVU
<Source>
OVU
<Output Channel>
UNSUBSCRIBE
ALL
SVU
<Source>
OVU
<Output Channel>
DATA
POWER
RUNNING / SLEEPING
PRESET
<Preset Number>
SLEVEL
<Source>
OLEVEL
<Output Channel>
XLEVEL
<Input Channel> <Source>
GLEVEL
<Loc/Net/Gen>
SMUTE
<Source>
OMUTE
<Output Channel>
XMUTE
<Input Channel> <Source>
GMUTE
<Loc/Net/Gen>
ZONERIN
<Output>
SVU
<Source>
OVU
<Output Channel>
GPI
<Input>
GPO
<Output>
EXTMUTE
ALARM_PROTECT
<Output Channel>
ALARM_FAULT
<Output Channel>
INFO_NAME
"<Device Name>"
INFO_MODEL
<Device Model>
INFO_VERSION
<Firmware Version>
INFO_MAC
<NET1/NET2>
<Output Channel>
Z_MONITOR
Z_MONITOR ERROR CODES
0
Z IN RANGE
1
Z ABOVE Z-MAX THRESHOLD
2
Z BELOW Z-MIN THRESHOLD
3
SHORT-CIRCUIT (PROTECTION ON)
4
OPEN- CIRCUIT
ERROR
0
TPNET_ERROR_NONE
1
TPNET_ERROR_INVALID_FIELD_TYPE
2
TPNET_ERROR_INVALID_FIELD_PARAM1
3
TPNET_ERROR_INVALID_FIELD_PARAM2
4
TPNET_ERROR_INVALID_FIELD_PARAM3
7
TPNET_ERROR_TIMEOUT_PONG
9
TPNET_ERROR_DISCONNECT_WHILE_UNCONNECTED
10
TPNET_ERROR_INVALID_CLIENT_IP
11
TPNET_ERROR_MESSAGE_TOO_LONG
12
TPNET_ERROR_UNSUPPORTED_MESSAGE
13
TPNET_ERROR_INVALID_RATE_VALUE
14
TPNET_ERROR_MAX_CLIENTS_REACHED
15
TPNET_ERROR_MASTER_MODE
<Level>
<Level>
<Output Channel>
<Level>
<Group>
<Level>
YES/NO
YES/NO
<Output Channel>
YES/NO
<Group>
<Source> or <Output> or <Aux>
<GPO Value>
<Value>
<Value>
<Output Channel>
<Value>
<Group>
<Value>
<Value>
<Output Channel>
<Value>
<Group>
<Level>
<Level>
<Output Channel>
<Level>
<Group>
YES/NO
YES/NO
<Output Channel>
YES/NO
<Group>
<Source> or <Output> or <Aux>
<Post Vumeter Level_Left>
<Post Vumeter Level_Right>
<Post Vumeter Level>
<GPI Value>
<GPO Value)
ON/OFF
ON/OFF
<Error Code>
Sets the Device Power status (Running / Sleeping)
Sets the current PRESET (0-10) 0=factory, 1-10=User
Sets the current LEVEL of an audio Source
Sets the current LEVEL of an Output Channel (Main:1~4, Aux: 4,5,
Digital: 6~10)
Sets the current LEVEL of a Matrix point
Sets the current LEVEL of a Group
Sets the current MUTE Status of an audio Source
Sets the current MUTE status of an Output Channel
Sets the current MUTE status of a Matrix Point
Gets the current MUTE of a Group
Sets zoner replica for given Output (1~4=Main, 5,6=Aux, 7~10=Digital).
For main outputs, can be S1~4, for Aux outputs, can be S1~4 and also
O1~4 (Main output 1~4), for Digital outputs can be S1~4, O1~4 and
also A1~2 (Aux out 1~2)
Sets the current value for a General Purpose Output
Increases the current LEVEL of an audio Source by Value (Value can
range from ±1 to ±100)
Increases the current LEVEL of an Output Channel by Value (Value can
range from ±1 to ±100) (Channel is Main:1~4, Aux: 4,5, Digital: 6~10)
Increases the current LEVEL of a Matrix point by Value (Value can range
from ±1 to ±100)
Increases the current LEVEL of a Group by Value (Value can range from
±1 to ±100)
Decreases the current LEVEL of an audio Source by Value (Value can
range from ±1 to ±100)
Decreases the current LEVEL of an Output Channel by Value (Value can
range from ±1 to ±100) (Channel is Main:1~4, Aux: 4,5, Digital: 6~10)
Decreases the current LEVEL of a Matrix point by Value (Value can
range from ±1 to ±100)
Decreases the current LEVEL of a Group by Value (Value can range from
±1 to ±100)
Subscribes to all VU-meters
Subscribes to an audio Source VU-meter
Subscribes to an Output Channel VU-meter
Unsubscribe to all VU-meters
Unsubscribes to an audio Source VU-meter
Unsubscribe to an Output Channel VU-meter
Shows the Device Power status
Shows the current PRESET
Shows the current LEVEL of an audio Source
Shows the current LEVEL of an Output Channel (Main:1~4, Aux: 4,5,
Digital: 6~10)
Shows the current LEVEL of a Matrix point
Shows the current LEVEL of a Group
Shows the current MUTE status of an audio Source
Shows the current MUTE status of an Output Channel
Shows the current MUTE status of a Matrix point
Shows the current MUTE of a Group
Shows current zoner replica for given Output (1~4=Main, 5,6=Aux,
7~10=Digital). For main outputs, can be S1~4, for Aux outputs, can be
S1~4 and also O1~4 (Main output 1~4), for Digital outputs can be
S1~4, O1~4 and also A1~2 (Aux out 1~2)
Shows the VU-meter value of an audio Source
Shows the VU-meter value of an Output Channel
Shows the current value of a General Purpose Input
Shows the current value of a General Purpose Output.
Shows the current value for External Mute
Shows the Protect alarm status of an Output Channel
Shows the self-diagnosis system alarm status of an Output Channel
Shows the Device Name
Shows the Device Model
Shows the Firmware Version
Shows the Device MAC address for NET1 or NET2 Ethernet interface
Web
HW
GUI
148