Télécharger Imprimer la page

BE Power Equipment BE2800i Manuel D'opérateur page 15

Publicité

OPERATION
BEFORE CONNECTING POWER
Make sure all electrical equipment, including wires and plugs, are in good
condition before connecting to the generator.
Make sure all loads driven by the generator are within the rated load
range.
Ensure the connected load is within the rated range for current.
ATTENTION: IT IS RECOMMENDED TO GROUND YOUR
GENERATOR BEFORE EACH USE. IF THE ELECTRICAL EQUIPMENT
REQUIRES IT, YOU MUST GROUND YOUR GENERATOR AS IT
CAN LEAD TO DAMAGE TO BOTH YOUR YOUR UNIT AND YOUR
EQUIPMENT.
CONNECTING POWER
1.
Start the engine.
2.
Turn eco mode switch to the "on" position.
3.
Insert plug into desired AC outlet.
4.
Ensure AC indicator light is on.
5.
Turn your equipment on.
tip: before increasing engine speed, eco mode must be off. if you are
connecting multiple loads to the generator, connect them from largest to
smallest, according to the electrical load.
GENERATOR GROUNDING
In order to prevent any damage to the generator caused by electric shock
or improper electric application, it is recommended that the generator is
grounded with a good conductor with insulating sheath.
1.
Use a grounding wire with sufficient electrical energy capacity.
2.
Connect one end of the grounding wire to the grounding bolt on the
generators control panel.
3.
Insert the grounding body (iron road with a diameter of 0.5 - 1cm) at least
20cm into the earth.
4.
Connect the other side of the grounding wire to the grounding body.
15

Publicité

loading

Ce manuel est également adapté pour:

Be4000i