Fastening by means of quick action bracing unit
In order to brace the drill rig by means of the quick action bracing unit, the distance
to the opposite wall must be between 1.7 m and 3 m.
K
I
Attention! It is important that the drill rig is firmly connected to the surface.
If not fixed correctly, injuries to the operator or damages to the drilling unit
may be caused. Uncontrolled movements during drilling will cause the drill
bit to hit the surface to be drilled which may lead to a chipping of the
segments. The drill bit might also tilt in the bore hole which consequently
will damage it.
Fixing the Core Drill Motor
Caution! When mounting the machine, risk of squashing.
Wear protective gloves!
Setting up the mounting plate
Position the drill rig. Position the quick action bracing unit
as close as possible behind the support on the base of the
rig or on the clamping head of the column. Fix the drill rig
by turning the crank (I) clockwise. Secure in position by
means of the appropriate bolt (K).
To clamp on the stand, the transport handle (H) must be
swung upwards.
Move the machine holder upwards until it locks in the top
position.
Use the turnstile to open the locking device of the
mounting plate (see arrow).
Remove it and connect it to the core drill motor as
described subsequently.
H
14