4.6
Service mode
Data
Mode
›
10 sec
H
S
›
›
Hardware
Software
version
version
005
5.12
Enter Service mode: Press "Data" for 10 seconds
→ Green status LED flashes
To show the next parameter, press "Mode"
Data query in each mode: press "Data" button
Exit Service mode: Press "Mode" button for 2 seconds
4.7
Error displays
If an error is detected both safety outputs are deactivated and symbols & and an error code are displayed.
1
2
The status LED lights up red.
Display
E001
Error
Sensor 1
wiring defective
Remedy
Check sensor 1
Should other fault messages appear, please contact your supplier.
5
Technical Data
Supply voltage
Power consumption
Inputs sensors
Safety outputs
Status output
Reaction time
(at activation)
SAFETY INSTRUCTIONS
It is the responsibility of the manufacturer to perform a risk assessment and install the detector and the door system in accordance with applicable national and international
regulations and safety standards and, if applicable, in accordance with the Machinery Directive 2006/42/EC.
The detector may be installed by professionally qualified personnel only. Repairs or attempted repairs by unauthorised personnel will void the warranty. Do not touch the electrical and
optical components.
Came S.p.A.- Via Martiri Della Liberta 15 - IT-31030 DOSSON DI CASIER (TV)
TEL (+39) 0422 4940 - FAX (+39) 0422 4941 - info@came.com - www.came.com
Came S.p.A. hereby declares that ECN3F242 complies with the essential requirements and other relevant provisions of the RoHS Directives 2011/65/EU,
RED 2014/53/EU, MD 2006/42/EC.
Original upon request.
COMMERCIAL PRODUCT
4
Back
Back to
to top
start
t
›
›
Type
3
E002
Sensor 2 wiring
defective
Check sensor 2
24 V AC/DC, ±15%
max. 3 VA
for sensors with 8,2 kOhm termination
Solid state relays, 24 V DC,
min. 0.5 mA, max. 50 mA
internally protected by a fuse
R
ca. 60 Ω
DS (on)
Solid state relays, 24 V AC/DC,
max. 50 mA, R
ca. 30 Ω
DS (on)
< 20 ms
U
o
›
Supply
Internal
voltage
temperature
value
value
In the service mode, further information can be displayed:
H Hardware Version
S Software Version
t Type (Cat. acc. to EN ISO 13849-1)
U Internal supply voltage
o Current chip temperature
E The last five error messages (displayed by pressing "Data")
E rES: press and hold "Data" button until --- is displayed to reset
the error messages
E006
E007
Configuration mode
incorrectly set
Outputs not OK
Check configura-
Check output wiring
tion
Start-up time
Dimensions
Mounting
Protection class
Operating temperature –20°C to +60°C
Storage temperature
Humidity
E
E
›
›
Errors
Errors
flash
flash
Error 5
rES
latest
Error 4
---
2 sec
Error 3
Error 2
Error 1
End
E008
E101
Undervoltage
Check supply
< 500 ms
22,5 x 94 x 88 mm (W x H x D)
Direct DIN-rail mounting
IP30
–40°C to +70°C
< 95% non-condensing
›
E102
Overvoltage