Télécharger Imprimer la page

CAME ECN3F242 Mode D'emploi page 7

Masquer les pouces Voir aussi pour ECN3F242:

Publicité

4.4
Diagnostic menu (read only)
Data
Mode
{
E
r
2 sec
Errors flash
Resistors
Error 5
1
latest
value
Error 4
2
value
Error 3
Error 2
Error 1
End
Enter Diagnostic menu:
Press "Mode" and "Data" buttons simultaneously for
2 seconds → Status LED flashes orange
To see the next parameter, press "Mode", Data query
(Mode E and r): press "Data"
Exit Diagnostic menu:
Press "Mode" button for 2 seconds
4.5
Function test
Function test
Outputs
Contacts
Unpowered
Safety output 1
OPEN
Safety output 2
OPEN
Status output
OPEN
Back
Back to
to top
start
S
S
Output 1
Output 2
1
1
1or E
1 or E
0
0
0 or E
0 or E
• Press sensor 1, check LED (orange), display (P
• Release sensor
• If present, press sensor 2, check LED, display (P
• Release sensor
After successful testing, the system is ready for operation.
Display: A and two flashing dots
Sensor 1
idle
CLOSED
S
C
h
both
Configu-
Fall-delay
outputs
ration
time
11
C
h
11 or E
001
002
00
00 or E
Access Configuration
E
last 5 error messages (displayed by pressing "Data")
r
current resistances of the sensors (kOhm): 1, 2, 4, 6, 8, 10, 12 or 14
S  shows the state of output 1:
output activated, 1 = okay, current flow; E = error, no current flow
(press "Data") output deactivated, 0 = no current flow; E = error, current flow
S  shows the state of output 2:
output activated, 1= okay, current flow; E = error, no current flow
(press "Data") output deactivated, 0 = okay, no current flow; E = error, current flow
S   s hows the state of both outputs:
outputs activated, 1 = okay, current flow; E = error, no current flow
(press "Data") outputs deactivated, 0 = okay, no current flow; E = error, current flow
C
shows the current configuration (active inputs):
001 = both inputs 1 and 2, 002 = only input 1, 003 only input 2
h
The holding time (extension of the output signal):
001 = none, 002 =100 ms, 003 = 200 ms, 004 = 500 ms, 005 = 1000 ms
C
configuration: entering into the configuration mode by pressing "data"→ chap. 4.3
, 1). Check if output 1 is open.
Sensor 1
Sensor 2
actuated
idle
OPEN
CLOSED
OPEN
C
Configu-
ration
con
con
(flashing)
(see chapter 4.3)
, 2). Check if output 2 is open.
Sensor 2
Sensor 1 + 2
actuated
idle
CLOSED
OPEN
CLOSED
OPEN
CLOSED
Fault
OPEN
OPEN
OPEN
3

Publicité

loading