4 - Electrical connection
4.1 - Establishing the
power supply
Condition:
Wireless receiver
Caution! Risk of damage due to excessive connection voltage!
Voltages exceeding 253 volts can damage electronic components. Ensure
that the nominal voltage of the network is 230 volts.
The infrared heater is equipped with a pre-wired wireless receiver and a
three-wire connection cable, 1.9 meters long, with a power plug attached
at the end.
Caution! Changes to the electrical connection of the pre-installed wire-
less receiver may only be made by a qualifi ed electrician!
- Connect the ground wire of the network to the yellow-green connecti
on wire of the infrared heater.
- Connect the live wire (phase) of the network to the terminal L.
- Connect the neutral wire of the network to the terminal N.
- Connect the terminal (
infrared heater.
- Connect the terminal (
infrared heater.
L) with the blue connection wire of the
N) with the brown connection wire of the
63