4.
Daily checking of the cutting machine
Items
Whether any of the components are damaged or
loosely connected;
Front
panel
Whether the output quick sockets are tightened;
Whether the abnormality indicator illuminates.
Whether the input power cable and buckle are in good
Back
condition;
panel
Whether the air intake is unobstructed.
Whether the bolts are loosely connected.
Cover
Side
Whether the side plate is loosely fixed.
plates
Whether the screws are loosely connected.
Chassis
Whether the machine enclosure has color fading or
overheating problems;
Whether the fan sounds normal when the machine is
Routine
running;
Whether there is abnormal smell, abnormal vibration or
noise when the machine is running.
Items
Whether the grounding wires (including work piece
Earth cable
GND wire and cutting machine GND wire) break off.
Whether the insulating layer of the cable is worn, or the
conductive part of the cable is exposed;
Cutting
Whether the cable is drawn by an external force;
cable
Whether the cable connected to the work piece is well
connected.
Checking requirements
Daily checking of the cables
Checking requirements
https://www.arccaptain.com/
Remarks
If unqualified,
check the interior
of the machine,
and tighten or
replace the
components.
If unqualified,
tighten or replace
the components.
If abnormal,
check the interior
of the machine.
Remarks
If unqualified,
tighten or replace
the components.
Use appropriate
methods
according to the
work site
situation to
ensure safety
and normal
cutting.