2.Connection of earth cable
Insert the quick plug on the earth cable into
the terminal and tighten it clockwise.
NOTICE: The ground clamp connector
MUST be tightly connected to the socket to
avoid power short circuit.
Ensure the ground clamp is connected
on clean, bare metal (not rusty or
painted).
Pic 8: Connection of earth cable
3. Connection of air compressor
Air hose interface
The CUT55 requires compressed air to be
attached to the unit. Use a hose clamp to
tighten the gas hose to avoid air leakage.
NOTICE: The input air pressure mini-mum
must be 72.5 PSl, 5 Bar and must not
exceed150 PSl, 10.3 Bar. An air regulator
is included with the unit with optimum
pressure setting set to 57.5 PSl, 4 Bar. The
unit is also equipped with an air filter which
captures water and oil vapor. The vapor
collected can be drained out of the bottom
of the unit by turning the drain button.
Pic9:Connection of air compressor
4. Connection of input power
The CUT55
operates in 240V or 120V
power supply. Plug the Power Cord into a
Cable
properly grounded. Set Cutting Gun down
on nonconductive, nonflammable surface
away from any grounded objects. And then
then turn the Power Switch ON. The fan
should start. The Digital screen should turn
on.
NOTICE: Adjust the Voltage Switch to
match the outlet voltage:
For 120VAC, attach the provided adapter
to the Power Cord.
For 240VAC, do not use the adapter. Plug
Pic10: Connection of input power
the Power Cord into a properly grounded
and rated receptacle matching the plug
and selected voltage. Need to be
connected to circuits with 50A and above
https://www.arccaptain.com/