6.1- Cleaning
• Disconnect the hose and all accessories from the compressor before cleaning.
• Whenever possible, keep safety devices free of dirt and dust. Wipe the equipment with a
clean cloth or blow it with compressed air at low pressure (max. 3 bar).
• Do not use aggressive detergents, chemicals or solvents for cleaning; these may be
aggressive to the plastic parts. Make sure no water can get into the interior of the product.
6.2- Maintenance
Condensed water
• Turn off the compressor and disconnect the hose and all accessories from it.
• Release any residual pressure in the tank.
• Loosen the drain plug and drain the condensed water every day after use.
• NOTE: The condensation water from the pressure tank may contain residual engine oil.
Collect and dispose of condensation water in an environmentally friendly manner at your local
collection point.
• Check and hand tighten the drain plug.
Safety valve
• The safety valve (7) has been set to the maximum permitted pressure of the pressure tank.
User should not adjust the safety valve.
Air intake filter
• The air intake filter (1) prevents dust and dirt from being drawn into the compressor. A
clogged filter will significantly reduce compressor performance.
• Clean the air intake filter every 300 hours of operation. Perform cleaning more frequently if
the environment is dusty.
• Remove the air filter from the air compressor, then open the filter housing. Use compressed
air (approx. 3 bar) to blow debris from the filter. Assemble and install the intake filter after
cleaning.
6.3- Troubleshooting
Problems
The compressor
does not start
The compressor
starts, but the tank
does not pressurize
(on pressure gauge,
11)
The compressor
starts and the tank
pressurized, but the
accessory does not
start
Possible causes
1. No input power
2. Insufficient power supply
3. Ambient temperature is too
low
4. Motor is overheated
1. The drain plug leaks
2. The seals are damaged
1. The hose connections leak
2. The quick-lock coupling (9)
leaks
Recommended solutions
1. Check the power cable, plug and mains
supply.
2. If extension cable is used, make sure it
is unwound and the thickness of the wire
is sufficient.
3. Never operate the compressor in
ambient temperature below +5 °C.
4. Allow the motor to cool down before
restart.
1. Hand tighten the screw and check the
air tightness again. Replace the screw at
service centre, if necessary.
2. Check the seals for leaks. Replace the
seals at service centre, if necessary.
1. Check the hoses and connections for
leaks. Replace, if necessary.
2. Check the quick-lock coupling for
leaks. Replace the part at service centre,
if necessary.