Télécharger Imprimer la page

Jandy Infinite WaterColors Serie Manuel D'installation page 10

Masquer les pouces Voir aussi pour Infinite WaterColors Serie:

Publicité

Jandy
Figure 5.
Remove Spa Light PCBA
8.
Replace the old light lens gasket with the new gasket provided
with PCBA.
Risk of Electrical Shock or Electrocution. Always install a new lens gasket whenever
disassembling the light. Failure to do so may permit water to leak into the assembly,
which could cause:
(a) An electrical hazard resulting in death or serious injury to pool or spa users, installers,
or others due to electrical shock, or
(b) A malfunction of the Jandy Infinite WaterColors LED Light, which likewise could result
in serious injury to pool or spa users, installers, or bystanders, or in damage to property.
9.
Apply thermal paste to the back of the new PCBA.
10. Place the new PCBA into the spa light housing, ensure wires
pass through the top opening of the PCBA.
11. Install the green ground wire to the stud marked "Earth" and
tighten nut.
12. Install the PCBA nut to the other stud.
13. Plug the blue connector terminal white wire to terminal N on the
new PCBA.
Page 10
Infinite WaterColors
®
WARNING
Pool & Spa LED Lights | Spare Parts Installation Manual

Publicité