INTELLISYS® CONTROL AND INSTRUMENTATION
PRIOR TO STARTING
1. Check coolant level. Add if necessary.
2. Make sure main discharge valve is open.
3. Turn on electrical isolator. The power L.E.D. will
illuminate and the display will indicate 'Ready to
start' .
Make sure that all protective covers are in place .
STARTING
Press 'Start' [24]. The compressor will start and then load
automatically.
8044766 Rev.A
INTELLISYS® OPTION
WARNING
POWER OUT RESTART (Optional)
If this setting is set to ON, the compressor will
automatically restart when power is returned to the
compressor if it was operating when power was removed.
POWER OUT RESTART TIME
If the power out restart setting is set to ON, this is the
number of seconds from the time power is restored until
the compressor starts. The power out restart horn will
sound during this time.
NORMAL STOPPING
1. Press 'Unloaded Stop'[25]. The compressor will
unload then stop.
2. Turn off electrical isolator.