Télécharger Imprimer la page

brennenstuhl RM L 3100 Mode D'emploi page 19

Publicité

Les langues disponibles
  • FR

Les langues disponibles

086215 Rauchwarnmelder RM L 3100.qxp_086215 BA_Rauchwarn
RM L 3100
Operating Instructions
The smoke detector then returns to normal
sensitivity.
Important:
If a malfunction is detected the device will beep
every 40 seconds.
Function test
The smoke detector is equipped with a test button.
Press the test button. The alarm sounds three
times, followed by a 1.5 second pause. This interval
is repeated until the button is released. If there is
no additional or other signal a defect has been
detected.
Remark:
If the smoke detector does not function properly
please contact our service department.
Maintenance and care
To ensure the functional reliability of the smoke
detector it must be serviced at least once a year,
as specified in DIN EN 14676. The following proce-
dure must be used:
– Dust the smoke detector with a soft cloth.
– If necessary, remove dirt with a damp cloth.
Do not use cleaning agents.
– Carry out a function test (see function test).
19

Publicité

loading