Télécharger Imprimer la page

Parkside PZM 2 A2 Instructions D'utilisation Et Consignes De Sécurité page 10

Publicité

Overload protection:
Max . allowable
input current:
Frequency range:
Response:
Measuring range: Resistance
Range
Resolution
200 Ω
2 kΩ
0 .001 kΩ
20 kΩ
0 .01 kΩ
200 kΩ
0 .1 kΩ
2 MΩ
0 .001 MΩ
20 MΩ
0 .01 MΩ
NOTE: While measuring resistance
of any circuit/component (especially
for low resistance), the resistance of
connecting test probes/cables have
to be taken into account for better
accuracy of measured value .
Diode test
Range
The display shows the approx .
forward voltage drop of the
diode under test .
Open circuit voltage:
approx . 2 .2 V
Test current: approx . 0 .6 mA
10 GB/IE/NI
250 mA / 600 V
fast fuse
200 mA
40 to 400 Hz
Average,
calibrated in
RMS of sine
wave
Accuracy
0 .1 Ω
±(1 .0 % +5)
±(1 .0 % +5)
±(1 .0 % +5)
±(1 .0 % +5)
±(1 .0 % +5)
±(1 .2 % +5)
Description
Continuity test
Resistance ≤ 30 Ω: The built-in
buzzer sounds .
Resistance ≥ 30 to ≤ 120 Ω:
The built-in buzzer may or may
not sound .
Resistance ≥ 120 Ω: The
built-in buzzer does not sound .
Safety
instructions
Before using the product, please
familiarise yourself with all the operating
and safety instructions . Please include all
documentation when passing this product
on to others .
m
WARNING: Choking hazard!
Packaging material (e .g . foils or
polystyrol) are not to be toyed with .
Keep children away from packaging
material . The packaging material is
not a toy .
Electrical products do not belong in
 
the hands of children . Person with
disabilities should also only use
electrical devices within the scope of
their abilities . Never allow children
or persons with disabilities to use
electrical products unsupervised . They
may not recognize potential risks .

Publicité

loading

Ce manuel est également adapté pour:

374236 2104