Airfusion Climate II Installation Instructions
Re-configure the factory default DIP switches setting in the remote so that the receiver and remote
D.
(transmitter) communication is on a different channel. The four DIP switches can be set in any (up or
down) resting position with an aid of a pen tip or small screw driver as shown below.
E.
Please repeat the (A)-(C) steps to check the function.
F.
If the issues still persist after following point (A) to (D) and there is still no control, then please contact the local
retailer for a new remote or transmitter.
NOTE: For your safety, a new receiver must be installed by a licensed electrician.
NOTE: While repairing the DC ceiling fan remote and receiver is in progress, the fan automatically operates at
highest speed in REVERSE mode for approximately 2 minutes and then operates in FORWARD mode for another
2 minutes. During the paring process, do not press any button on the remote.
WOBBLE:
NOTE: ceiling fans tend to move during operation due to the fact that they are mounted on a rubber grommet. If the fan
was mounted rigidly to the ceiling it would cause excessive vibration. Movement of a few centimetres is quite acceptable
and DOES NOT suggest any problem.
TO REDUCE THE FAN WOBBLE: Please check that all screws which fix the mounting bracket and down rod are secure.
BALANCING KIT: A balancing kit is provided to balance the ceiling fan on initial installation. Please refer to the instruction
on how to use the balancing kit. The balancing kit can be used to assist re-balancing should the ceiling fan become un-
balanced again. Store your balancing kit away after installation for future use if required.
12 | P a g e
AFTER INSTALLATION