The pump is not suited to discharge saltwater, faeces, inflammable, etching, explosive or
other hazardous liquids. Please observe the max. temperature of the liquids to be discharged
stated in the technical data.
Inside the pump, lubricants are used which may contaminate the liquids being discharged in
case of any improper operation or damage of the device. The lubricants used are biologically
degradable and non-hazardous to health.
3.
Technical data
Model
Mains voltage / frequency
Nominal performance
Protection type
Pressure port
Max. flow rate *
Max. pressure
Max. delivery height *
Max. submersion depth
Max. size of the solids being pumped
Max. fluid temperature
Max. cut-in frequency in one hour
Connection cable
Cable type
Weight (net, incl. connection cable)
Min. self-priming level (A) **
Min. suction level (B) **
Cut-in level (C) **
Cut-out level (D) **
Item no.
*
The indicated maximum performance values were obtained with a clear, non-reduced outlet.
**
The values between brackets refer to the illustrations given at the end of these operating instructions.
4.
Installation
4.1. General installation information
During the entire process of installation, the device must not be connected to the electrical
mains.
The pump and the entire connection system have to be protected from frost.
All connection lines have to be perfectly tight since leaking lines may affect the performance of the pump and
cause considerable damage. If required, please use a suitable sealant to make the installation airtight.
When tightening threaded connections, please do not apply excessive force which may cause damage. When
laying the connection pipes, you should make sure that the pump is not exposed to any form of weight, vibration
or tension. Moreover, the connection lines must not contain any kinks or an adverse slope.
4.2. Installation of the pressure line
The pressure line will convey the liquid from the pump to the point of withdrawal. To avoid friction losses, please
use a possibly large pressure line - ideally, its diameter should match that of the pump outlet.
To facilitate installation, the scope of delivery includes a two-piece multi-dimensional connecting bend (10)
providing the following connection options: ½ threaded male port for 33,25 mm (1") and 26,44 mm (3/4"), hose
connector for 28 mm and 34 mm.
When adapting the connection to the pressure line, please remove the narrower and thus unnecessary parts of
the multi-dimensional connection piece at the cutting points provided for this purpose (a, b). To cut off these
superfluous parts we recommend the use of a commercially available saw. When connecting to the male thread
with 33.25 mm (1"), only the bend of the reduction piece is needed.
DRAIN 6000/36
230 V ~ 50 Hz
950 Watt
IP X8
41.91 mm
, male
(1 ¼ ")
6,000 l/h
3.4 bar
34 m
7 m
2 mm
35° C
30, evenly distributed
10 m
H07RN-F
9.1 kg
120 mm
27 mm
420 mm
230 mm
30136