%C6KERRDETECT-SP-4-SWBUSSTALL_RECOVERED: The switching bus stall is recovered and
data traffic switching continues.
Commandes supplémentaires pour une vérification plus approfondie.
6500#remote command switch show nvlog
NVRAM log:
26. 02/28/2013 03:46:22: sp_error_detection_recover_sup:Supervisor detected
non-recoverable Switch BUS stall error
30. 01/28/2014 04:00:43: sp_error_detection_recover_sup:Supervisor detected
non-recoverable Switch BUS stall error
6500#remote command switch show fabric timeout
**** Timeout Error info.*****
Timeout Threshold: 1
Powercycle recovery enabled
Wait time for stall_wait: 3 sec.
Wait time for swbus_check: 3 sec.
Wait time for swbus_recheck: 3 sec.
Wait time for accept: 3 sec.
Wait time for debounce: 5 sec.
Wait time for throttle: 5 sec.
Time when Last stall was removed: 3w6d
I: The error received from the fabric was ignored
Un arrêt prolongé du bus peut provoquer un plantage du superviseur. Vous verrez des journaux
similaires à ceux ci-dessous lorsque cela se produit.
*May 28 18:25:34.515 PDT: %C6KERRDETECT-SP-4-SWBUSSTALL: The switching bus is
experiencing stall for 60 seconds
00:01:58: SP: -------------------------------------------------------------------------
00:01:58: SP: Supervisor Processor crashing due to unrecoverable switching bus stall
00:01:58: SP:
There may be poorly inserted cards on the system
00:01:58: SP:
And there is NO real clue which card is causing the switching bus stall
00:01:58: SP: -------------------------------------------------------------------------
%Software-forced reload
Conclusion
Veuillez suivre les meilleures pratiques décrites ci-dessus pour l'insertion et le retrait en ligne des
modules. Inspectez les modules/châssis et, en cas d'endommagement, contactez le centre
d'assistance technique de Cisco pour savoir si une RMA est nécessaire. N'insérez pas de carte de
ligne endommagée.