2
When the timer is activated, push the on/off button to
check the time left or to reset the set time.
3
When the product is in timer mode it is started and
stopped by the thermostat, depending on the
ambient temperature, in the same way as in normal
operating mode.
Note! The timer is reset to zero if there is a power failure.
4.7 Memory function
1
After a power failure the product runs in the mode
that was activated before the last standby period. The
product needs to be manually started after the power
is cut.
4.8 Overheating guard
Note! The product is equipped with an overheating guard.
If the ambient indoor temperature is higher than 50°C in
standby mode or in the operating mode; all outputs will be
switched off. 10 long audio prompts will be heard, and the
display shows FF and flashes at 1 Hz for 75 seconds.
● The product cannot be restarted when the safety
function is activated, even if the ambient temperature
drops below 50°C. you must reset the product.
4.8.1 To reset the product
● Stop the product and pull out the plug.
● Connect the product and start it again.
4.9 Stop the product
● Push the on/off button on the control panel to put the
product in standby mode. Pull out the plug and wait until
the product has cooled.
4.10 To move the product
● Stop the product and pull out the plug. The product is
equipped with wheels for easier transportation.
5
Storage
Store the product in a dry area, protected from direct
sunlight and wet conditions.
6
Maintenance
Warning! Any repairs should be carried out by an
authorized service center or other qualified personnel.
Warning! Stop the product and pull out the plug,
wait until all parts have become completely cool before you
handle, move, clean or do maintenance to the product.
● Keep the radiator flanges clean and free from dust, which
can affect the emission of heat. Wipe off dust and dirt
with a damp cloth. Do not use detergent or abrasive
agents or utensils.
● Do not scratch the paint, this can cause the radiator
flanges to corrode.
7
Disposal
7.1
To discard the product
● Make sure that you follow local regulations when you
discard the product. Do not burn the product.
8
Technical data
Specification
Voltage
Power settings
Cable length
Dimension Wx Hx D
Value
230 ~50 Hz
2000 W
1.8 m
39.3 x 64 x 28 cm
9