Télécharger Imprimer la page

Publicité

Liens rapides

Sivoia QS Drapery System
Installation Guide—Please Read Before Installing
Important Notes - Please Read Before Installing
A. Lutron systems are intended for use with only Lutron hardware and
power supplies.
B. Codes: Install in accordance with all local and national electrical
codes.
C. Environment: Ambient operating temperature: 32 °F - 104 °F (0 °C
- 40 °C), 0 - 90% humidity, non-condensing. Indoor use only.
D. Plan the installation to maintain sufficient clearance between the
moving drapery and any object, including window hardware,
cranks, lock levers, and stationary drapery.
! CAUTION: RISK OF FALLING OBJECTS. Securely install the
shade system per the mounting instructions.
Failure to do so could result in minor or moderate injury.
Tools required:
• Tape measure
• Small flat-blade screwdriver
• #1 Phillips screwdriver
• #2 Phillips Screwdriver
System Components:
Drapery Track
Single-track, right-draw, pinch pleat system shown; dual systems will include additional track(s) and EDU(s)
Included with
wall-mount tracks:
Extendable
Wall-Mount
Bracket, Single*
Included with
ceiling-mount tracks:
Ceiling-Mount
Cam-Lock with Washer*
*Quantity varies with system width
Customer Assistance
USA and Canada: 1.844.LUTRON1 (588-7661) | UK: +44.(0)20.7702.0657 | lutron.com/help | support@lutron.com
For product warranty information, please see: lutron.com/TechnicalDocumentLibrary/Window Systems Warranty.pdf
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
• Power drill and drill bits
• Level
• Pliers
• 3/32 in hex key (included
w/recess-mount system)
Included with dual
wall-mount
tracks:
Extendable
Wall-Mount
Bracket, Dual*
Included with recess-mount tracks:
Recess-Mount
Bracket*
12/2023
P/N 045700 Rev. C
Contents
1
Wall Mount _________________________________ 2
2
Ceiling Mount ______________________________ 3
3
Recess Mount ______________________________ 4
4
Drive Installation ____________________________ 5
5
Pinch Pleat Fabric Installation ________________ 5
6
Ripple Fold Fabric Installation ________________ 7
7
Ripple Fold (without Pull-to-Start) _____________ 9
8
Ripple Fold (with Pull-to-Start) _______________ 11
9
Power-Up and Control Assignment ___________ 12
10
Setting Open and Close Limits ______________ 12
11
Optional Manual Open Feature______________ 13
O
Restoring Factory Default Settings ___________ 14
Terminal Block
#8 x 1½ in
Wood Screw*
English
Electronic Drive Unit (EDU)
EDU Models:
QSSC-EDU-D105
24-36 V- 41 W
QSSC-EDU-D105-P 24-36 V- 41 W
QSSC-EDU-D145
24-36 V- 40 W
QSSC-EDU-D175
24-36 V- 45 W
Page 1

Publicité

loading

Sommaire des Matières pour Lutron Sivoia QS

  • Page 1 Installation Guide—Please Read Before Installing Contents Important Notes - Please Read Before Installing A. Lutron systems are intended for use with only Lutron hardware and Wall Mount _________________________________ 2 power supplies. B. Codes: Install in accordance with all local and national electrical Ceiling Mount ______________________________ 3 codes.
  • Page 2 Sivoia QS Drapery System Installation Guide Wall-Mount 1.1 Mount the brackets: IMPORTANT: The drapery track must be level to operate properly, so all brackets must be aligned along a level horizontal line. Each wall-mount bracket must be installed into a wall stud or other structural member using appropriate fasteners. Ensure brackets are mounted firmly enough to support the combined weight of the drapery track, EDU, and fabric.
  • Page 3 Sivoia QS Drapery System Installation Guide Ceiling-Mount IMPORTANT: Each ceiling-mount cam-lock must be installed into a structural member using an appropriate fastener. Ensure the structural member is of sufficient strength to support the combined weight of the drapery track, EDU, and fabric.
  • Page 4 Sivoia QS Drapery System Installation Guide Electronic Drive Unit (EDU) Installation IMPORTANT: A drapery track with recess-mount brackets must be installed into a structural member using wood screws. Ensure the structural member is of sufficient strength to support the combined weight of the drapery track, EDU, and fabric.
  • Page 5 5.1 Attaching hooks: Lutron recommends a drapery hook setting of 1/2 in (13 mm) from the top of the drapery to the top of the hook (hooks not included). This locates the drapes just below the track and prevents it from rubbing on the track. It is recommended that a distance of 1/2-1 in (13-25 mm) be maintained between the bottom of drapery panel and the floor.
  • Page 6 Sivoia QS Drapery System Installation Guide Pinch Pleat Fabric Installation (continued) 5.2 Hang the drapery - left and right draw systems: Attach the drapery to the drapery track starting with Idle End Auxiliary Carriers Drive End the Master Carrier, attaching the last two hooks of the drapery to the EDU bracket hooks.
  • Page 7 Sivoia QS Drapery System Installation Guide Ripple Fold Fabric Installation 6.1 Drapery Panel Height Drapes are typically sized so the bottom of the drapery track and top of the drapery panel are located 4 in (101 mm) above the window casing.
  • Page 8 Sivoia QS Drapery System Installation Guide Ripple Fold Fabric Installation (Continued) 6.3 Configurations One-way draw Auxiliary snap locations One-way draw Master Carrier Drive-end snap bracket (all auxiliary carriers (non-Pull-to-Start carriers (accepts 3 male snaps) accept male snaps) accept 3 male snaps,...
  • Page 9 Left draw and right draw configurations require one fabric panel. Center draw and tandem center draw configurations require two fabric panels. The Lutron ripple fold drapery system is compatible with Graber snap tape, which has a spacing of 4.25 in (108 mm) between snaps.
  • Page 10 Center draw and tandem center draw configurations require two drapery panels. The lutron ripple fold drapery system is compatible with Graber snap tape, which has a spacing of 4.25 in (108 mm).
  • Page 11 Sivoia QS Drapery System Installation Guide Ripple Fold | Drapery Tape Assembly (with Pull-to-Start) The Lutron ripple fold drapery system is compatible with standard ripple fold snap tape with spacing of 4.25 in (108 mm) between snaps. • Standard carriers accept male snaps; quantity required varies with track width.
  • Page 12 Power Up the Drapery and Assign a Control 9.1 Initial Power-Up: For detailed system wiring, programming, and troubleshooting information, please refer to P/N 045314 Sivoia QS Wiring & Connect the power supply to an appropriate power source. Programming Guide. The LED on the EDU will flash a red/green/blue pattern as To find the meaning of LED blink codes, see: the EDU powers up.
  • Page 13 Sivoia QS Drapery System Installation Guide The Optional Manual Open Feature Note: The Manual Open feature is only available in systems that were originally ordered with the option. The following instructions do not apply to the standard Master Carrier. NOTE: The Manual Open feature is not available with Pull-to-Start.
  • Page 14 | Support@Lutron.com Tel: +44.(0)20.7702.0657 | Fax: +44.(0)20.7480.6899 (Importer) Technical Support: +44.(0)20.7680.4481 | Freephone: 0800.282.107 04/2024 Lutron, the Lutron logo, and Sivoia are trademarks or registered trademarks of Lutron Electronics Co., Inc. in the U.S. and other countries P/N 045700 Rev. C...
  • Page 15 24-36 V- 45 W * La quantité varie selon la largeur du système Assistance à la clientèle États-Unis et Canada: 1.844.LUTRON1 (588-7661) | UK: +44.(0)20.7702.0657 | lutron.com/help | support@lutron.com Pour les informations concernant la garantie, consultez : lutron.com/TechnicalDocumentLibrary/Window Systems Warranty.pdf Page 1 Lutron Electronics Co., Inc.
  • Page 16 Guide d’installation du système de rideau Sivoia QS Montage mural 1.1 Montez les supports : IMPORTANT: La piste de rideau doit être de niveau pour fonctionner correctement. Tous les supports doivent donc être alignés le long d’une ligne horizontale à plat. Chaque support de fixation mural doit être installé dans un montant mural ou un autre élément structural à...
  • Page 17 Guide d’installation du système de rideau Sivoia QS Montage au plafond IMPORTANT : Chaque verrou à came monté au plafond doit être installé dans un élément structural à l’aide d’une fixation appropriée. Assurez-vous que l’élément structural est suffisamment résistant pour supporter le poids combiné de la piste de rideau, de l’EDU et du tissu.
  • Page 18 Guide d’installation du système de rideau Sivoia QS Montage encastré : IMPORTANT : Une piste de rideau avec les supports encastrés peut être installé dans un élément structural avec des vis à bois. Vérifiez que l’élément structural est suffisamment résistant pour supporter le poids combiné du piste de rideau, de l’EDU et du tissu.
  • Page 19 5.1 Attacher les crochets : Lutron recommande un réglage des crochets de rideau de 13 mm (1/2 po) entre le sommet du rideau et le sommet du crochet (crochets non inclus). Cela positionne les rideaux juste en-dessous du piste et les empêche de frotter contre le piste. Une distance de 13 à...
  • Page 20 Guide d’installation du système de rideau Sivoia QS Installation de tissu à plis pincés (suite) 5.2 Suspendre le rideau – système avec ouverture à droite et à gauche : Attachez le rideau au piste de rideau à partir du Extrémité de Extrémité...
  • Page 21 Guide d’installation du système de rideau Sivoia QS Installation du tissu plis ondulés 6.1 Hauteur du panneau de rideau Les rideaux sont généralement dimensionnés de façon à ce que la partie inférieure des rideaux coulissants et la partie supérieure du panneau de rideau se trouvent à 101 mm (4 po) au-dessus du chambranle de la fenêtre. Il faut parfois ajuster l’emplacement pour tenir compte de la hauteur et de l’application spécifiques du panneau de rideau.
  • Page 22 Guide d’installation du système de rideau Sivoia QS Installation du tissu plis ondulés (suite) 6.3 Les configurations Traction à sens unique Support principal pour traction à sens unique Emplacement des boutons-pression auxiliaires Support boutons-pression (les supports sans la fonctionnalité Tirer pour démarrer (les patiences acceptent les extrémité...
  • Page 23 à ouverture depuis la gauche et depuis la droite nécessitent un panneau en tissu. Les configurations à ouverture depuis le centre et à ouverture en tandem depuis le centre nécessitent deux panneaux en tissu. Le système de rideaux à plis ondulés Lutron est compatible avec le ruban à...
  • Page 24 Les configurations à ouverture depuis le centre et à ouverture en tandem depuis le centre nécessitent deux panneaux de rideau. Le système de rideaux à plis ondulés Lutron est compatible avec le ruban à boutons-pression Graber comprenant un espacement de 108 mm (4,25 po).
  • Page 25 Plis ondulés | Ensemble de ruban de rideaux (avec la fonctionnalité Tirer pour démarrer le déplacement) Le système de rideaux à plis ondulés Lutron est compatible avec le ruban à boutons-pression standard pour plis ondulés comprenant un espacement de 108 mm (4,25 po) entre les boutons-pression.
  • Page 26 Guide d’installation du système de rideau Sivoia QS Activer l’électricité de la piste et attribuer un contrôle 9.1 Mise en marche initiale : Pour des informations détaillées sur le câblage, la programmation et le dépannage du système, veuillez consulter le Guide de câblage et Connectez l’alimentation à...
  • Page 27 Guide d’installation du système de rideau Sivoia QS La fonction optionnelle d’ouverture manuelle REMARQUE: La fonction Ouverture manuelle n’est disponible que sur les systèmes commandés à l’origine avec l’option. Les instructions suivantes ne s’appliquent pas au support principal standard. REMARQUE : La fonction d’ouverture manuelle n’est pas disponible avec la fonctionnalité Tirer pour démarrer le déplacement.
  • Page 28 Tél. : +44. (0)20.7702.0657 | Télécopieur : +44. (0)20.7480.6899 Soutien technique : +44. (0)20.7680.4481 | Numéro gratuit : 0800.282.107 04/2024 Lutron, le logo Lutron, et Sivoia sont des marques commerciales de Lutron Electronics Co., Inc., enregistrées aux États-Unis et dans d’autres pays. N° de pièce 045700 Rév. C...