AUTOMATIC AIR CONDITIONING STATION R1234yf
AC 8344
AUTOMATIC AIR CONDITIONING STATION R134a
AC 8544
STATION MANAGEMENT
This menu contains a number of functions enabling
the user to perform regular self-maintenance, such
as:
- internal tank charging and filling
- self-cleaning cycles
- decontamination cycle
- scale test function
FILLING THE BOTTLE
Use this cycle to charge or refill the internal receiver.
One input is required, which is the quantity of
refrigerant to be charged. Please consider that,
depending on the length of the hose, a greater
quantity of refrigerant will be charged. For a length
of 3 m, the final charge will be about 300/400
grams more than the set value.
INTERNAL WASHING
This cycle performs an internal refrigerant rinse
to clean the internal circuit, removing oil and dirt.
After rinsing, the cycle performs an oil drain and
internal vacuum. Regular use of the AUTO-CLEAN
cycle can improve the station's efficiency and
service life.