PROTECTION FUNCTION
Protection function
e This unit is equipped with a protection
function for protecting this unit and
your speakers from various accidents
or problems that can occur.
e When the protection function
activates, the unit stops operating and
the power indicator lights green to
indicate that the protection function Is
activated.
The protection function
activates in the following
situations:
e When a speaker output contacts
ground.
-
e When the unit malfunctions and a DC
signal is sent to the speaker outputs.
e When the temperature of internal
parts exceeds 120°C (248°F),
e When a ground lead of the center unit
(cassette receiver, CD receiver, etc.)
or this unit is not connected to a
metal part serving as an electrical
ground passing electricity to the
batterv's minus © terminal.
{In this case, the power indicator does
not light.)