CONTROLLING THE HEATER
All certified control panels with thermal control may be used in
controlling the heater. The output of the heater must remain in the
interval determined by the control panel's producer.
Product can be used only with controlunit with timer function.
Including other than those for installation in public saunas, shall be
provided with a timer. For appliances for use in blocks of flats, hotels
and similar locations, the operating period of the sauna heater shall
be limited to 12 h with a minimum rest period of 6 h before any
automatic restarting. For other appliances, the operating period
of the timer shall be limited to 6 h, automatic restarting not being
allowed.
GUARD RAILS
It is recommended to construct a guard rail around the heater.
We recommend using materials with low heat capacity and bad
thermal conductivity for the guard rail.
Upon using flammable materials, it is necessary to leave the
specified minimal safety clearances between the heater and
flammable constructions.
ATTENTION!
IF THE HEATER IS INSTALLED CLOSER TO FLAMMABLE
CONSTRUCTIONS THAN AT THE DISTANCE OF THE MINIMAL REQUIRED
PROTECTION BELT IT MAY CAUSE A FIRE HAZARD!
SAUNA ROOM
Wall materials and insulating the sauna room
In a sauna with electric heating, all massive heat accumulating wall
surfaces (brick, glass brick, rendering etc.) must be insulated to use
the electric heater with a regular output.