Connecting the heater to the power supply
•
A method to disconnect all poles from the mains (a circuit
breaker) must be installed on the power circuit before the sauna
controller.
•
Only a certified electrician is allowed to connect the heater to the
power supply.
•
The power cable of the heater must meet the requirements of
UL 62 in US and CSA 49 in Canada.
•
It is recommended to connect the unit to the mains without an
earth-leakage circuit breaker.
•
The maximum current intensity in the cross-sectional area of the
cable and circuit breaker are listed in Table 2.
•
The cable must be secured to the clamp on the cover screw.
Attention!
It is forbidden to use a non-heat-resistant cable with PVC
isolation as the power cable. The joint box must be waterproof and it
must be located up to 19.7 in (50 cm) from the floor.
•
Open the cover of the heater's electrical box.
•
Attach the power cable on the terminal block according to the
circuit diagram.
•
Close the cover.
•
Fix the cable on the output with a cable strap.
HIVE Mini 6
HIVE Mini 9
HIVE Mini 11
6
L1 L2
240V 2~
208V 2~
HIVE 12
HIVE 15
HIVE 18
240V 2~
208V 2~
L1
L1
L2
L2