ELEVATEUR TUBULAIRE MAT 150
CODE : B505003-0097
4.2
Maintenance
Every day
Clean elevator
After cleaning, check all security elements (casing,
limit switch...) are clean, in their own place and in
start of running
Every weeks
For the regulator filter
Check the regulator filter level
Check the condensator level and drain it if it is
necessary
Check the order of the filter, change it if it is
necessary
Check the oil level in the lubrificator (if the system
is equipped), put oil if it is necessary
Grease the pivoting arm (B049780E) with oiler
BGR0003
Grease the bowl locking collar pin( code
B01033101 and B010315) grease with the
grease BGR0003
See locking collar B010320E10
Use an UNIL polyfood 2 usda H1 grease (VMI code:
GRA021)
MACHINE : 143174
BE CAREFUL, USING AN OTHER GREASE IS TO BANISH
VMI - Pétrins & Mélangeurs
Zone Industrielle Nord - 85607 MONTAIGU
Tél : 33 (0)2 51 45 35 35 Fax : 33 (0)2 51 06 40 84
Http : //www.vmi.fr – E-mail : comm.ind@.vmi.fr
Date création : 13-02-06
Date révision :
400V-50HZ
Version notice : Indice
AND RISK TO DAMAGE PINS
Page 18 sur 46