ELEVATEUR TUBULAIRE MAT 150
CODE : B505003-0097
3
COMMISSIONING
3.1
Setting up
 The connection between the mixer to the power
supply through a circuit breaker fixed on a wall and
the ground, make do it by specialist
 Insert the power cable (supplied by others) into the
electrical panel
 Connect supply cable to L1, L2 and L3 terminals in the
cabinet (see picture) and also grounding
Check and tighten terminals L1, L2, L3 and PE
 Close the electrical panel
 The control panel fixed on the fence must be
connected to the electric power, and check that
the supply and the one indicated in the panel are
the same.
 Turn the main section switch on 1. Check that the
bowl lifts up by pressing once S1. If it does not lift
up, turn the main section switch on 0. Before to
disconnect any thing, It is important to check
there is not electric current any more. Invert two
of the three phases of the supply and connect
MACHINE : 143174
Câble d'alimentation à
raccorder
Power cable to connect
Zone Industrielle Nord - 85607 MONTAIGU
Tél : 33 (0)2 51 45 35 35 Fax : 33 (0)2 51 06 40 84
Http : //www.vmi.fr – E-mail : comm.ind@.vmi.fr
400V-50HZ
again the elevator on the electric current. Check
that the bowl lifts up.
VMI - Pétrins & Mélangeurs
Date création : 13-02-06
Date révision :
Version notice : Indice
Page 13 sur 46
Sheet 13 sur 46

Publicité

loading