12.3 ANOMALIES DE FONCTIONNEMENT CAUSES-SOLUTIONS
ANOMALIE
VIS SANS FIN DE CHARGEMENT DES GRANULÉS BLOQUÉE PAR UN CORPS
ÉVACUATION DES FUMÉES BOUCHÉE OU AVEC TERMINAL EMPÊCHANT LE
TERMINAL D'ÉVACUATION BOUCHÉ, CAR LE PASSAGE DES FUMÉES EST EMPÊCHÉ
LES GRANULÉS NE
TOMBENT PAS DANS LE
BRASERO
UN COUP DE VENT PROLONGÉ A DÉTERMINÉ LA MISE EN SÉCURITÉ DE
LE MOTEUR DE CHARGEMENT DES GRANULÉS NE FONCTIONNE PAS
LA PORTE DE LA CHAMBRE DE COMBUSTION DE L'APPAREIL EST OUVERTE
ÉVACUATION DES FUMÉES BOUCHÉE OU AVEC TERMINAL EMPÊCHANT LE
DES GRANULÉS
S'ACCUMULENT DANS LE
BRASERO PENDANT LE
LA PORTE DE LA CHAMBRE DE COMBUSTION DE L'APPAREIL N'EST PAS ÉTANCHE,
FONCTIONNEMENT
GRANULÉS AVEC DÉPÔT SUPÉRIEUR À LA NORMALE OU DE MAUVAISE QUALITÉ
CE PHÉNOMÈNE SE PRODUIT LORS DU PREMIER ALLUMAGE, CAR LE VERNIS
SI L'APPAREIL PRODUIT DE LA FUMÉE AU BOUT DE 25 MINUTES : LE BRÛLEUR EST
L'APPAREIL PRODUIT DE
LA FUMÉE DANS LE MILIEU
SI L'APPAREIL PRODUIT DE LA FUMÉE AU BOUT DE 25 MINUTES : ALLUMAGE
L'APPAREIL SE MET EN
ALLUMAGE RETARDÉ, CAR LA VIS SANS FIN DE CHARGEMENT EST VIDE
ALARME QUELQUES
MINUTES APRÈS LA
CONCLUSION DE LA
ALLUMAGE EFFECTUÉ AVEC UN LARGE RETARD, CAR LE BRASERO EST SALE
PHASE DE START
L'APPAREIL NE S'ALLUME
PAS
L'ORIFICE DE LA BOUGIE D'ALLUMAGE EST BOUCHÉ PAR DES RÉSIDUS DE LA
L'APPAREIL FONCTIONNE AVEC DE FRÉQUENTS ALLUMAGES/EXTINCTIONS
DÉPÔT DE SUIE NOIR SUR
LA VITRE
Manuel d'installation, d'utilisation et d'entretien
CAUSE PROBABLE
LE RÉSERVOIR EST VIDE
ALARME « NO PELLET » SUR L'AFFICHEUR
ÉTRANGER, P. EX. CLOU, NYLON, MORCEAU DE BOIS
ALARME « NO PELLET » SUR L'AFFICHEUR
PASSAGE DES FUMÉES
ALARME « SMOKE NO OUT » SUR L'AFFICHEUR
PAR L'INSERTION D'UNE GRILLE OU D'UN TERMINAL
ALARME « SMOKE NO OUT » SUR L'AFFICHEUR
L'APPAREIL.
ALARME « SMOKE NO OUT » SUR L'AFFICHEUR
ALARME « NO PELLET » SUR L'AFFICHEUR
LE THERMOSTAT RÉARMABLE EST INTERVENU EN BLOQUANT LE
MOTORÉDUCTEUR
ALARME « ALARM T. MAX » SUR L'AFFICHEUR
ALARME « SMOKE NO OUT » SUR L'AFFICHEUR
PASSAGE DES FUMÉES
LE BRASERO EST PARTICULIÈREMENT SALE
LE JOINT EST USÉ
SILICONE DE L'APPAREIL SÈCHE
L'INSTALLATION DE SORTIE DES FUMÉES N'EST PAS ÉTANCHE
SALE, L'ALLUMAGE EST EFFECTUÉ AVEC UN LARGE RETARD
RETARDÉ, CAR LA VIS SANS FIN DE CHARGEMENT ÉTAIT VIDE
LE CLAPET DE SURPRESSION EST INTERVENU
ALARME « FAILED START » SUR L'AFFICHEUR
ALARME « FAILED START » SUR L'AFFICHEUR
LA BOUGIE D'ALLUMAGE NE FONCTIONNE PAS
ALARME « FAILED START » SUR L'AFFICHEUR
GRANULÉS ÉPUISÉS DANS LE RÉSERVOIR OU VIS SANS FIN VIDE
ALARME « FAILED START » SUR L'AFFICHEUR
LE TIRAGE DU CARNEAU EST EXCESSIF
ALARME « FAILED START » SUR L'AFFICHEUR
COMBUSTION
DES GRANULÉS S'ACCUMULENT DANS LE BRASERO
LE TIRAGE DU CARNEAU EST TROP FAIBLE
GRANULÉS DE MAUVAISE QUALITÉ
NATURAL 12
SOLUTION
NETTOYER LE BRASERO EN PROCÉDANT COMME INDIQUÉ
DANS CE MANUEL D'UTILISATION ET D'ENTRETIEN, PUIS
REMPLIR LE RÉSERVOIR À GRANULÉS
COUPER L'ALIMENTATION ÉLECTRIQUE ET RETIRER LE CORPS
ÉTRANGER DU RÉSERVOIR
NETTOYER LE BRASERO EN PROCÉDANT COMME INDIQUÉ
DANS CE MANUEL D'UTILISATION ET D'ENTRETIEN, PUIS
CONTRÔLER L'ÉVACUATION DES FUMÉES, CAR ELLE POURRAIT
ÊTRE SALE OU BOUCHÉE
NETTOYER LE BRASERO EN PROCÉDANT COMME INDIQUÉ
DANS CE MANUEL D'UTILISATION ET D'ENTRETIEN, PUIS
RETIRER LE TERMINAL ET LE REMPLACER PAR UN AUTRE
APPROPRIÉ
NETTOYER LE BRASERO EN PROCÉDANT COMME INDIQUÉ
DANS CE MANUEL D'UTILISATION ET D'ENTRETIEN, PUIS
COUPER L'ALIMENTATION DE L'APPAREIL ET LE REMETTRE
SOUS TENSION
REMPLACER LE MOTEUR DE CHARGEMENT DES GRANULÉS
APRÈS AVOIR VÉRIFIÉ ET ÉLIMINÉ LES CAUSES DE LA
SURCHAUFFE, ATTENDRE QUE L'APPAREIL REFROIDISSE ET
RÉARMER LE THERMOSTAT
FERMER LA PORTE DE LA CHAMBRE DE COMBUSTION
NETTOYER LE BRASERO EN PROCÉDANT COMME INDIQUÉ
DANS CE MANUEL D'UTILISATION ET D'ENTRETIEN, PUIS
CONTRÔLER L'ÉVACUATION DES FUMÉES, CAR ELLE POURRAIT
ÊTRE SALE OU BOUCHÉE, OU RETIRER LE TERMINAL ET LE
REMPLACER PAR UN TERMINAL APPROPRIÉ
NETTOYER LE BRASERO EN PROCÉDANT COMME INDIQUÉ
DANS CE MANUEL D'UTILISATION ET D'ENTRETIEN
FERMER CORRECTEMENT LA PORTE DE LA CHAMBRE DE
COMBUSTION OU REMPLACER LE JOINT
NETTOYER LE BRASERO ET PARAMÉTRER LE PROGRAMME DE
FONCTIONNEMENT LEVEL 2, EN PROCÉDANT COMME INDIQUÉ
DANS CE MANUEL D'UTILISATION ET D'ENTRETIEN SI ÇA NE
SUFFIT PAS, UTILISER DES GRANULÉS D'UNE AUTRE QUALITÉ
FAIRE FONCTIONNER L'APPAREIL À PLEIN RÉGIME PENDANT
QUELQUES JOURS
VÉRIFIER L'ÉTANCHÉITÉ DU CARNEAU ET EN PARTICULIER
S'ASSURER DU BON ÉTAT DES TUYAUTERIES D'ÉVACUATION ET
DES JOINTS
NETTOYER LE BRASERO EN PROCÉDANT COMME INDIQUÉ
DANS CE MANUEL D'UTILISATION ET D'ENTRETIEN
NETTOYER LE BRASERO EN PROCÉDANT COMME INDIQUÉ
DANS CE MANUEL D'UTILISATION ET D'ENTRETIEN, PUIS
REMPLIR LE RÉSERVOIR À GRANULÉS
SUIVRE SCRUPULEUSEMENT TOUTES LES CONSIGNES DE
NETTOYAGE ET D'ENTRETIEN ORDINAIRE ET EXTRAORDINAIRE
FOURNIES DANS CE MANUEL D'UTILISATION ET D'ENTRETIEN
NETTOYER LE BRASERO EN PROCÉDANT COMME INDIQUÉ
DANS CE MANUEL D'UTILISATION ET D'ENTRETIEN, PUIS
REMPLIR LE RÉSERVOIR À GRANULÉS
NETTOYER LE BRASERO EN PROCÉDANT COMME INDIQUÉ
DANS CE MANUEL D'UTILISATION ET D'ENTRETIEN, PUIS
REMPLIR LE RÉSERVOIR À GRANULÉS
NETTOYER LE BRASERO EN PROCÉDANT COMME INDIQUÉ
DANS CE MANUEL D'UTILISATION ET D'ENTRETIEN, PUIS
REMPLACER LA BOUGIE
NETTOYER LE BRASERO EN PROCÉDANT COMME INDIQUÉ
DANS CE MANUEL D'UTILISATION ET D'ENTRETIEN, PUIS
REMPLIR LE RÉSERVOIR À GRANULÉS
FAIRE CONTRÔLER LE TIRAGE DU CARNEAU
NETTOYER LE BRASERO EN PROCÉDANT COMME INDIQUÉ
DANS CE MANUEL D'UTILISATION ET D'ENTRETIEN
NETTOYER LE BRASERO ET PARAMÉTRER LE PROGRAMME DE
FONCTIONNEMENT LEVEL 2, EN PROCÉDANT COMME INDIQUÉ
DANS CE MANUEL D'UTILISATION ET D'ENTRETIEN SI ÇA NE
SUFFIT PAS, UTILISER DES GRANULÉS D'UNE AUTRE QUALITÉ
L'APPAREIL DOIT FONCTIONNER PLUS LONGTEMPS EN
RÉDUISANT LES ALLUMAGES ET EXTINCTIONS
FAIRE CONTRÔLER LE TIRAGE DU CARNEAU ET APPORTER LES
MODIFICATIONS ÉVENTUELLEMENT NÉCESSAIRES
NETTOYER LE BRASERO ET PARAMÉTRER LE PROGRAMME DE
FONCTIONNEMENT LEVEL 2, EN PROCÉDANT COMME INDIQUÉ
DANS CE MANUEL D'UTILISATION ET D'ENTRETIEN SI ÇA NE
SUFFIT PAS, UTILISER DES GRANULÉS D'UNE AUTRE QUALITÉ