Télécharger Imprimer la page

Hoover HTP634DB3 Mode D'emploi page 12

Publicité

Power Management Function
it is possible to set a maximum power absorption level for the induction hob, choosing up
to different power ranges.
induction hobs are able to limit themselves automatically in order to work at lower power
level, to avoid the risk of overloading.
Turn on the hob, then Press at the same time the "+" (timer) and key lock.
The timer indicator will show " P5" which means power level 5. The default mode is on 7.0
Press at the same time + (timer) and key lock for
confirmation.
To enter Power Management Function
To switch to another level
or
Confirmation and Exit Power Management Function
Then the hob will be turned off.
10
/ 7.1
.

Publicité

loading

Ce manuel est également adapté pour:

H634db3tp/g3