4 - TEchNIcAL SPEcIFIcATIONS
Model
Air inlet pressure (bar•)
Maximum working pressure (bar•)
Maximum rated flow (l/min)•
Air connection (standard*)
Oil connection (standard*)
Max. weight (kg)
Reservoir capacity / usable capacity (l)
Dimensions (mm)
Noise level
Recommended oil types
Model
Air inlet pressure (bar•)
Maximum working pressure (bar•)
Maximum rated flow (l/min)•
Air connection (standard*)
Oil connection (standard*)
Max. weight (kg)
Reservoir capacity / usable capacity (l)
Dimensions (mm)
Noise level
Recommended oil types
Model
Air inlet pressure (bar•)
Maximum working pressure (bar•)
Maximum rated flow (l/min)•
Air connection (standard*)
Oil connection (standard*)
Max. weight (kg)
Reservoir capacity / usable capacity (l)
Dimensions (mm)
Noise level
Recommended oil types
193551052 ver.10 - UPD 22012020
hP 250
hP 500
250
500
2,0
1,3
1/4" GAS
3/8" - 18 NPTF
~ 1,4 / 1,1
Pump dimensions are shown on page 2, figure 1a
80 dB(A) / 1m
MOBIL DTE 11 - SHELL TELLUS OIL T 15
CASTROL HYSPIN AWH15 - or equivalent
hP 250
hP 500
SL Tank
SL Tank
250
500
2,0
1,3
1/4" GAS
3/8" - 18 NPTF
~ 2,5 / 2,1
Pump dimensions are shown on page 2, figure 1b
80 dB(A) / 1m
MOBIL DTE 11 - SHELL TELLUS OIL T 15
CASTROL HYSPIN AWH15 - or equivalent
hP 250
hP 500
XL Tank
XL Tank
250
500
2,0
1,3
1/4" GAS
3/8" - 18 NPTF
~ 4 / 3,5
Pump dimensions are shown on page 2, figure 1c
80 dB(A) / 1m
MOBIL DTE 11 - SHELL TELLUS OIL T 15
CASTROL HYSPIN AWH15 - or equivalent
hP 700
hP 1000
5 ÷ 8
700
1000
0,7
0,6
~ 5,3
hP 700
hP 1000
SL Tank
SL Tank
5 ÷ 8
700
1000
0,7
0,6
~ 7,8
hP 700
hP 1000
XL Tank
XL Tank
5 ÷ 8
700
1000
0,7
0,6
~ 8,8