Setting:
In P2 mode, press and hold
Press
++
button to select from d1 tod7(Monday to Sunday).
Press
++
button to confirm day setting, display ++ (℃) flash, press ++ or ++
button to set temperature from 5℃ to 35℃;
Press
++
button again to confirm temperature setting, display
++
or
++
button to set running hours(from 0 to 24, means 00:00 to 24:00);
Press ++
button again to set temperature and hour until you set to 24:00; Press
++
button to set d2(Tuesday), and repeat the operations until all 7 days are set.
For better understanding, please see below example:
Tuesday
00:00 to 07:00, desired temperature 20℃
07:00 to 17:00, desired temperature 10℃
17:00 to 24:00, desired temperature 25℃
Setting as below:
In P2 mode, press and hold ++ 3 seconds →Press ++ and select 2 → Press ++
→ Press ++ and select 20 → Press ++ → Press
07:00, 20℃)
Continue press ++ →Press
select 17 (07:00 to 17:00, 10℃)
Continue press ++ →Press
select 24 (17:00to24:00,25℃), d2(Tuesday) setting finished → Press ++ to set
d3(Wednesday)
Anti-frostmode:Maintain the temperature at 7℃. Please note no matter in which
mode, if room temperature is lower than 7℃, the anti-frost mode will start running.
4.Timer
Press
++ , then press ++
In any modes, if set timer, when time is up, the heater will turnoff.
5.Open window function
The heater has an open window function.
Default setting of open window function is closed.
After you turn on the heater, press ++ button, display show ++ , then press ++
button to set open window function on, display show ++ , and press ++ button to
set open window function off, display show ++ then press ++ button to save
setting, or wait 10 seconds to save automatically.
Open window function description:
If you open a window widely in the space where the heater is located and the
temperature drop 2℃or more than 2℃ in two minutes, a sensor will detect the sharp
drop in temperature. The heater will switch out automatically and show ++
display.
The heater will come back to the previous mode after 10 minutes. However you can
manually restart the heater by pressing ++ button, and the heater will comeback
to the previous mode. The icon ++ disappears on display.
6.Resetting the heater to factory default
Turn off the heater's mains witch.
Press and hold ++ while you turn on the heater's main switch.
7.Maintenance
1) For cleaning, always unplug the heater and leave it to cool.
++ button 3 seconds, display show ++ .
++
and select 10 → Press
++
and select 25 → Press
or ++ button to set timer from 0 to 24hours.
6
++
++
and select 7(00:00 to
++
→Press ++ and
++ → Press ++ and
flash, press
in