4 Press OK to confirm.
On the display the day is flashing.
5 Turn the dial button to set the day.
6 Press OK to confirm.
On the display the hour is flashing.
7 Turn the dial button to set the hour.
8 Press OK to confirm.
The minutes are flashing on the display.
9 Turn the dial button to set the minutes.
10 Press OK to confirm.
The valve turns in the product and 'ins' is shown on the display. The product is now ready
to be mounted on the radiator.
Notice!
• Do not press OK again before the product is mounted on a heater.
• When you wait too long with the setting of the date or the time, the product takes it for
granted that the settings have been completed. The valve turns again in the product.
6 Assembly and installation
Notice!
• Follow the steps of chapter 5 if you have not done so already.
• Do not press OK before the product is assembled on a radiator.
• The water from the heating system needs not to be drained when assembling the
product.
6.1 Preparation for assembly
• If present, remove the old tap of the radiator. Consult the manual or website of the
manufacturer for an exact description.
Notice! Turn the tap to close before removing it. Remove the tap by turning it counter-
clockwise.
• For assembly on a standard valve, follow the steps in paragraph 6.2 and for a Danfoss
valve, follow the steps in paragraph 6.3.
6.2 Assembly on a standard valve
1 Pull out the fixing ring until a 'CLICK' is heard.
2 Push the product onto the radiator.
3 Fasten the fixing ring by turning it clockwise.
The product is now mounted to the radiator.
22 User maual –wireless climate control
All manuals and user guides at all-guides.com
4 Press the OK button.
When properly mounted the home screen appears on the display. With an incorrect assembly,
an error code (F1, F2 or F3) appears. See chapter 'Failure' for more information.
6.3 Assembly on a Danfoss valve
First, determine which of the three Danfoss rings (RA/IPR/RAVL) should be placed on the valve
of the radiator. Fix these rings tightly and then place the smart thermostat head.
The radiator contains recesses; make sure that the Danfoss ring fits securely.
• Be careful not to catch your fingers between the two parts of a Danfoss ring during
Danfoss RA ring
1 Place the RA ring around the valve of the radiator.
2 Bolt on the RA ring using the supplied screw and nut.
Danfoss RAV ring
1 Place the RAV cap (F) to the valve on the radiator.
2 Bolt on the RAV ring using the supplied screw and nut.
The valve actuation turns out from the product. 'AdA' appears on the display.
WARNING
installation.
Notice! Place the Danfoss ring so that it engages tightly in the recess (E) on the radiator.
Notice! Place the Danfoss ring so that it engages tightly in the recess (E) on the radiator.