Weld starting screen:
Counter (not
modifiable by an
operator)
Start welding
Modify program
Print program
Adjustment screen:
Join
experience
SAS au capital de 135 720 € - RCS Romans B414 581 363 – Code APE 2841 Z – Siret 414 581 363 00028 – TVA FR13414 581 363
English
If AVC-OSC:
- Go to the middle: Electrode moves back at
the maximum, then moves closer at the
maximum, and then moves to the middle. This
function is useful to avoid touching an end
stop during the welding. BE CAREFUL:
Check that nothing will be in the electrode
stroke
- « OSC Test » simulates the movement of the
electrode during the cycle
This button automatically returns the AVC to
the position at which the last weld was started.
On this screen, you can:
-
Change from weld to test and the reverse
-
Set or not a beep before ignition to warn
of the creation of the arc.
-
See electrode information (and, if using a
closed head, positioning buttons for
electrode change)
330B Route de Portes Les Valence - 26800 Etoile sur Rhône
Tél: +33 475 575 070 - commerce@axxair.com - www.axxair.com
- 79 -
Machine angle.
Press to reset it
Left rotation
Adjustment screen
Right rotation