Manual torch mode :
Join
experience
SAS au capital de 135 720 € - RCS Romans B414 581 363 – Code APE 2841 Z – Siret 414 581 363 00028 – TVA FR13414 581 363
English
This mode allows you to use the SAXX as a
manual TIG station. This mode should only be
used if the manual torch is connected to the
"AUX" connector.
Trigger on this screen starts the welding cycle.
On this screen, it is possible to set the high
current (at the top of the screen) and at the
bottom of the screen the pregaz and postgaz
time.
It is also possible to start / stop the inerting line
if it is available.
Press the button on the right to access the
options.
Manual
Torch
- 2T / 4T: In 2T, the stop of the welding is done
on the release of the trigger whereas in 4T, the
stop is made by pressing again on the trigger.
- Choice between HF and Lift: In HF, the arc is
created without contact whereas in Lift it is
necessary to touch the part to weld and then to
go
up
to
create
- It is possible to set upslope and downslope
times to raise and lower the current for a certain
time at the beginning and end of welding.
- Pulse: allows to choose between smooth or
pulsed current. If pulsed, the percentage of the
low current and the pulse time have to be
defined
on
the
- Tacking time: allows to define a time at the end
of which the welding ends even if the stop was
not requested by the trigger.
330B Route de Portes Les Valence - 26800 Etoile sur Rhône